Lucent Technologies 6.1 Manuale Utente

Pagina di 588
MERLIN LEGENDCommunications System Release 6.1
System Planning  
555-661-112  
Issue 1
August 1998
Lines/Trunks 
Page 3-5
Identifying Line/Trunk Jacks 
3
Planning Form Instructions
3
Refer to the completed Control Unit Diagram on Form 1 to mark line/trunk jack 
types on Form 2c:
1.
For each module with line/trunk jacks noted in the Control Unit Diagram 
(beginning with Slot 01), write in the type of module and its slot number in 
the Module Type and Slot No. column of Form 2c; after the appropriate 
Log. ID number, draw a line to indicate the logical IDs (and therefore, the 
line/trunk jacks) that correspond to that module.
If the system has 100D (DS1) modules, keep in mind that even though the 
module has only one physical jack, the 100D module supports up to 24 
endpoints. Therefore, 24 logical IDs and associated line/trunk numbers are 
assigned to each module.
The 800 NI-BRI module supports up to 16 endpoints, therefore 16 logical 
IDs and associated line/trunk numbers are assigned to each 800 NI-BRI 
module even though the module has only eight physical jacks.
2.
In the Jack Type column of Form 2c, for all modules except 100D modules, 
write the jack type for each logical ID. Use the codes shown in 
Table 3–2
.
Table 3–2. 
Codes for Line/Trunk Jacks
3.
For systems that include a 100D module, do 
one of the following in the 
Jack Type column:
If the module will emulate trunks or will be used for digital data 
transmission, write the appropriate jack type code (see 
Table 3–2
for the channels being used (for example, 
T1-LS
T1-TIE
, or 
T1-S56
), 
or write 
T1
 if the channels are not being used at this time.
If the module will connect services (such as, Megacom and 
Megacom 800), write 
PRI
 for all 24 logical IDs of PRI-type modules.
You may now match incoming trunks to the available jacks as described in the 
next section.
1. T1 Switched 56 digital data is also available using T1-Tie trunks. See the “Tie Trunks” 
section later in this chapter.
Jack Type Code
Line/Trunk Type
LS
Loop-start
GS/LS
Ground-start/loop-start
DID
DID
Tie
Tie
T1-GS
DS1 connectivity used to emulate GS
T1-LS
DS1 connectivity used to emulate LS
T1-Tie
1
DS1 connectivity used to emulate tie or for digital data service
T1-DID
DS1 connectivity used to emulate DID
T1-S56
DS1 connectivity used for digital data
PRI
DS1 connectivity used for PRI service
BRI
NI-1 BRI