Mitsumi electronic 55K Manuale Utente

Pagina di 63
41
Precautions for Maintenance and Inspection
PROT
ECTIVE FUNCTIONS
3
*Values in parentheses indicate those for 400V class.
Power supply side power 
P
1
At R2/L1, S2/L2 and T2/L3 
and across R2/L1-S2/L2, 
S2/L2-T2/L3, and T2/L3-R2/
L1
Electrodynamic type 
single-phase wattmeter
P
1
 = W
11
 + W
12
 + W
13
 
(3-wattmeter method)
Power supply side power 
factor Pf
1
Calculate after measuring power supply voltage, power supply side current and power supply side 
power.
Converter output side 
voltage
Across P/L+-N/L-
Moving-coil type 
(such as tester)
Converter LED display lit
1.35 
× V
1
Maximum 380V (760V) during 
regenerative operation
Reset
Across RES (+) -SD
Moving-coil type (Tester, 
etc. may be used) 
(Internal resistance: 
50k
Ω or larger)
20 to 30VDC when 
open.
ON voltage: 1V or 
less (Note)
SD is common.
Alarm signal
Across A-C 
Across B-C
Moving-coil type  
(such as tester)
Continuity check
<At OFF>
<At ON> 
Across A-C: Discontinuity Continuity
Across B-C: Continuity
Discontinuity
Note: When a 24VDC power supply is connected across P24-SD.
Item
Measuring Point
Measuring Instrument
Remarks 
(Reference Measured Value) *
3
 
V
1
 
×
 
I
1
P
1
Pf
1
100
×
%