Mitsumi electronic 55K Manuale Utente

Pagina di 63
44
Standard Specifications
4.1 Standard Specifications
4.1.1
Model specifications
200V class 
Ty
p
Heat sink outside mounting 
structure
FR-CV-
K
7.5
11
15
22
30
37
(Note 4)
55
(Note 4)
Enclosure inside installation 
structure
FR-CV-
K-AT
Applicable inverter 
capacity (Note 1)
kW
7.5
11
15
22
30
37
55
HP
10
15
20
30
40
50
75
Out
put
Applicable current (A) (Note 1)
33
46
61
90
115
145
215
Regenerative 
braking torque
Short-duration 
rating
150% torque 60s
Continuous 
rating
100% torque
Po
wer
 sup
p
ly
Rated input AC voltage, 
frequency
Three phase 200 to 220V 50Hz, 200 to 230V 60Hz
Permissible AC voltage 
fluctuation
Three phase 170 to 242V 50Hz, 170 to 253V 60Hz
Permissible frequency 
fluctuation
±5%
Power supply system capacity 
(kVA) (Note 2)
17
20
28
41
52
66
100
Protective structure  (JEM 1030)
Open type (IP00)
Cooling system
Forced air cooling
Approximately weight 
(kg (lbs))
Heat sink 
outside 
mounting 
structure
5.0
(11.0)
5.0
(11.0)
6.0
(13.2)
9.5
(20.9)
10.5
(23.1)
34
(75.0)
38
(83.8)
Enclosure 
inside 
installation 
structure
6.5
(14.3)
6.5
(14.3)
7.5
(16.5)
12.5
(27.6)
13.5
(29.8)
Input signal
Reset
Output signal
Ready output signal, inverter run enable signal, converter reset, alarm signal
Protective functions
Overcurrent protection, overvoltage protection, electronic overcurrent protection, 
undervoltage, phase failure, CPU alarm, instantaneous power failure alarm, power 
supply alarm
Envir
onment
Ambient temperature
-10°C to +50°C (14°F to 122°F) (non-freezing)
Ambient humidity
90%RH or less (non-condensing)
Storage temperature
-20°C to 50°C (-4°F to 122°F)
Ambience
Indoors (free from corrosive gas, flammable gas, oil mist, dust and dirt)
Altitude
Maximum 1000m (3280.80feet) above sea level for standard operation.
After that derate by 3% for every extra 500m (1640.40feet) up to 2500m 
(8202.00feet) (91%).
Vibration
5.9m/s
or less
Dedicated stand-alone reactor
FR-CVL-
7.5K
FR-CVL-
11K
FR-CVL-
15K
FR-CVL-
22K
FR-CVL-
30K
FR-CVL-
37K
FR-CVL-
55K