BEFORE YOU BEGIN:
Review the fl ueing confi gurations in Figures A, B and C on 
the next page.  
F. 
Slim Line Wall Thimble
1. Assembling Slim Line Trim Ring and Heat Shield
2. Installing Slim Line Trim Ring and Heat Shield
Figure 5.14 
  
Lay the trim ring on fl at surface and bend up the six welded 
brackets into a 90 degree position. The brackets along the 
outer edge of the ring are for locating the ring in the center 
of the hole.
Figure 5.15
  
The heat shield is shipped fl at and must be hand bent into a 
half circle before attaching it to the trim ring. Bend the heat 
shield as shown.
Figure 5.16
  
Attach the heat shield to the trim ring with the four screws 
provided. Screws go through the heat shield and into the 
brackets on the trim ring.
Figure 5.17
   
When installing the trim ring/heat shield assembly make 
sure the trim ring is centered in the hole and that the shield 
is above the pipe. There must be a minimum of 2 cm mini-
mum clearance maintained to combustibles from the top of 
the heat shield. 
Measure from the fl oor to the center of the fl ue pipe. Cut 
out a 25.4 cm hole in the wall. Hold the trim ring/heat shield 
assembly in place and put a mark on the shield with a black 
marker where it protrudes through the exterior wall. Figure 
A
 on the next page. 
Use that mark as a guide to trim off excess heat shield with 
a pair of sheet metal shears.
Ensure that framing on the inside of the wall is a minimum 
inner framing diameter of 25.4 cm x 25.4 cm.
The four trim ring mounting screws provided should be 
replaced with appropriate fasteners for stucco, brick, con-
crete, or other types of sidings.
CAUTION
Sharp Edges
•  Wear protective gloves 
and safety glasses during 
installation.