3M 965AMS Manuale Utente

Pagina di 204
 
97
3M™ Dynatel™ Advanced Modular System 965AMS 
Measurement Functions
RFL>Wet Pulp>Operation
7.  DTS—Distance to the strap 
(far end). 
DTF—Distance to the fault. 
DSTF—Distance from the 
strap to the fault.
 Press 
Avg. Result
 to view a 
summary of test results.
8.  Use the results of this test 
to find the distance or run 
the test multiple times and 
the tester will average the 
distances.
RFL>Wet Pulp>Error Screens
1.  Swap the Red and Black 
test leads.