Elkay ERC8-1B/2B Dépliant

Pagina di 2
96602C (Rev. D)
ERC8-1B/2B, TRC8-1B/2B
NOTE:
  
It is important to insure proper ventilation.  Allow a
minimum clearance of 6 inches (152 mm) in front and 3 inches
(76mm) in the rear of the unit.  If unit is to be installed in an
enclosure, allow the following clearances around unit - 1 inch
(25mm) each side, 3 inches (76mm) in the rear, 3 inches
(76mm) inches above wall.
This chiller has been designed for use with potable water and
includes an o-ring seal on the drain plug.  This fitting should be
replaced if the unit is to be used with more aggressive fluids.
ERC8-1B/2B, TRC8-1B/2B
Refrigeration Packages
Installation Instructions
TEMPERATURE
ADJUSTMENT
1/4" (6 mm) O.D.
TUBE OUTLET
1/4" (6 mm) O.D.
TUBE INLET
ELECTRICAL
3/8" (9 mm) O.D.
TANK DRAIN
ELKAY MANUFACTURING COMPANY  -  2222 CAMDEN COURT  -  OAK BROOK, IL 60523  -  630.574.8484
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620