A DISPLAY OFF mode is available through the control 
panel. This mode allows you to control whether the 
display (Figure 4, 3) will be ON or OFF whenever the 
door is closed. The icon touch sequence that follows will 
switch between both modes:
NOTE: These are product temperatures, not air 
temperatures.
1. Touch and hold the WARMER icon (Figure 4, 2), and 
within five seconds press the POWER icon (Figure 
4, 1)
 three times.
2. The display will be either visible or dark when the door 
is closed.
3. To return to the previous mode, repeat Step 1. 
Temperature Display Selection
U-Line products supplied for 110 VAC operation have 
temperatures displayed in a default Fahrenheit (°F) 
configuration (Figure 4, 3). Models supplied for 220 VAC 
operation have temperatures displayed in a default 
Celsius (°C) configuration.
The display can easily be adjusted for either type of 
temperature display. Press and hold the LIGHT icon 
(Figure 4, 5) and within five seconds press the COOLER 
icon (Figure 4, 4) three times to change the display as 
desired.
Temperature Display
To display actual temperatures:
1. Press and hold the WARMER icon (Figure 4, 2) for 
approximately five seconds and release when the °F 
symbol in the display (Figure 4, 3) begins to flash.
2. After approximately 10 seconds, the display will return 
to the set-point temperature. 
Checking Product Temperature
Figure 5
To check the actual product temperature in your unit, 
insert an accurate thermometer into a plastic (non-
breakable) bottle that is partially filled with water. 
Tighten the bottle cap securely (Figure 5).
Place the bottle in the desired area for 24 hours. Refrain 
from opening the unit during the testing period. After 24 
hours, check the temperature of the water. If required, 
adjust the temperature control in a small increment (See 
ADJUSTING TEMPERATURE). 
Factors which affect the internal temperatures of the 
cabinet include:
• Temperature setting.
• Ambient temperature where installed.
• Number of times and length of time the door is 
opened and closed.
• Installation in direct sunlight or near a heat source.
Adjusting Temperature
IMPORTANT
IMPORTANT
Adjust the set-point temperature in single 
increments, and wait 24 hours for the temperature 
to stabilize before rechecking.