U-Line 2175WCOL Manuale Utente

Pagina di 180
3-43
Section 3 - Service and Repair
CLRCO2175
COMPRESSOR/COIL SPECIFICATIONS
DANGER
DANGER
Electrocution can cause death or serious injury. Burns from 
hot or cold surfaces can cause serious injury. Take precautions 
when servicing this unit.
• Disconnect the power source.
• Do not stand in standing water when working around 
electrical appliances.
• Make sure the surfaces you touch are not hot or 
frozen.
• Do not touch a bare circuit board unless you are 
wearing an anti-static wriststrap that is grounded to 
an electrical ground or grounded water pipe.
• Handle circuit boards carefully and avoid touching 
components.
To measure the start winding resistance, measure across the C and 
S pins.
To measure the run winding resistance, measure across the C and 
R pins.
Also check S to R and you should get the sum of the run and start 
windings.
To ensure the windings are not shorted, check the S and R to 
ground.
Figure 27. CLRCO2175
Water Valve
275 Ohms
Bypass Coil 
300 Ohms
Pump Motor
72 Ohms
Refrigeration coils  
150 Ohms
THERMISTORS
Four thermistors are employed. A type 1 thermistor is  used to 
measure the condenser temperature and determine the freeze and 
harvest cycles in conjunction with the custom electronic board. A 
type 2 thermistor is used to measure the ice bin, refrigerator, and 
evaporator temperatures.
REED SWITCH 
A reed switch is mounted to the underside of the cabinet and a 
magnet is mounted to the door. When the door is closed the 
magnet trips the switch which turns the light and display off. This 
also sets an audible warning.
DEFROST 
For the refrigerator defrost information, please refer to page 3-40.
ULIN_0576_AW 
R S 
OVERLOAD PROTECTOR 
STARTING RELAY 
RELAY COVER 
FF7.5HBK
Voltage
115.0
Frequency
60.0
LRA
25.5
FLA
4.0
Start Winding
11.2
Run Winding
2.2
Capacitor
N/A