3-63
Section 3 - Service and Repair
10. Once pushed completely into the opening finish routing the drain 
tubing to the desired location. Common installations use a floor 
drain, standpipe, garbage disposal, or Y-branch tailpiece-type drain 
connection (Figure 73 - 76). After the installation is complete, 
check the unit to ensure it is level both side to side and front to 
back. For disposal connections an optional adapter may be 
required (included with the kit) to adapt from the 7/8" connection.
11. For the gravity/floor drain or the standpipe drains it is important to 
secure the drain tubing to those items to prevent it from coming 
loose. For the disposal or 
Y-branch tailpiece connections press the drain tube over the 
barbed end on the connector. Make sure the knockout inside the 
tailpiece has been removed for both types of connections. Attach 
these two with a worm drive hose clamp. Depending on the size of 
the 
Y-branch or disposer fitting an adapter may be needed to interface 
between the 5/8" hose and connection.  
12. After all connections have been completed turn the unit to the ON 
position. Pour one gallon of water into the ice bin and check all drain 
connections for leaks. During this time also ensure that the water 
flows from the bin.  If the water does not flow from the bin there 
may be a problem with the drain connection such as kinks or 
improper slope. If your unit has a drain pump an indicator of P1 on 
the display will alert to a slow or clogged drain. If any problems are 
found, retrace the drain connection, correct the issue and retest 
with water.
Figure 73
Figure 74
Figure 75
Figure 76
Waste 
Cold 
Water 
Shut-Off 
Valve 
Hot 
Water 
Air Gap 
(Optional Hook-Up) 
Y-Branch Tailpiece
P60 Pump Required
ULIN_0600a_A
Cold 
Water 
Hot 
Water 
Waste
Waste 
Shut-Off 
Valve 
Standpipe
P60 Pump Required
Air gap must 
be left between
drain line and
water level.
ULIN_0598a_A
Air Gap 
(Optional Hook-Up) 
Cold 
Water 
Hot 
Water 
Waste 
Shut-Off 
Valve 
Disposal
P60 Pump
Required
ULIN_0599a_A
Waste 
Waste 
Cold 
Water 
Shut-Off 
Valve 
Hot 
Water 
Floor Drain
Air gap must 
be left between
drain line and
water level.
ULIN_0597a_A