Troubleshooting Guide
DANGER
ELECTROCUTION HAZARD
Never attempt to repair or perform maintenance on 
the unit until the main electrical power has been 
disconnected.
NOTE: Recommended temperature setting is 38°F.
Troubleshooting - What to check when problems occur:
PROBLEM
POSSIBLE CAUSE
REMEDY
Unit does not operate and 
electronic display is blank.
No electrical supply
Plug unit in or check circuit breaker.
No interior light
Loose or burned out bulb
Tighten or replace bulb (See MAINTENANCE; LIGHT 
BULB REPLACEMENT).
Electronic display is blank and 
interior light is OFF with door OPEN.
Unit is in blackout/Sabbath mode 
(not Star K certified) lighting mode.
Exit blackout/Sabbath mode (not Star K certified) 
(See OPERATION; INTERIOR LIGHT CONTROL).
Electronic display is blank and 
interior light is ON with door OPEN.
A display function has changed.
Touch and hold the warmer temperature button and 
touch and release the POWER button three times, then 
release the temperature button. The display should 
become visible.
Electronic display shows repeating, 
randomly flashing symbols and 
partial characters.
A factory control mode has been 
inadvertently entered.
Touch and hold the warmer temperature button and 
touch and release the LIGHT button three times, then 
release the temperature button to exit the factory 
control mode. The set-point temperature should now 
be displayed.
Electronic display shows:
0, 1 to 26, or 99.
A factory control mode has been 
inadvertently entered.
Repeatedly touch the warmer temperature button to 
advance any number shown to 99 and touch and 
release the LIGHT button. The set-point temperature 
should now be displayed.
Electronic display shows E3.
Door has been left open longer than 
20 minutes.
Close door completely. The set-point temperature 
should now be displayed.
Electronic display shows one or 
more of the following:
E1, E2, E4, E5, E6, E7, E8, E9, E10, P1. 
The unit is displaying an error code.
Record the error code(s) displayed and call for service.
Unit not cold enough. Check 
temperatures (See OPERATION for 
approximate temperatures).
Control set too warm
Set control to a cooler setting (See OPERATION). Allow 
24 hours for temperature to stabilize.
Airflow to front grille blocked
Airflow must not be obstructed to front grille (See 
OPERATION).
Dirty condenser coils
Clean condenser (See MAINTENANCE; CONDENSER 
CLEANING).
Door gasket not sealing properly
Door adjustment required (See MAINTENANCE; DOOR 
ALIGNMENT CHECK AND ADJUSTMENT).
Inaccurate temperature reading
Properly check temperature (See OPERATION).
Unit is too cold. Check temperatures 
(See OPERATION for approximate 
temperatures)
Control set too cold
Set control to a warmer setting (See OPERATION). Allow 
24 hours for temperature to stabilize.
The unit frosts up.
High ambient temperatures or 
humidity
Defrost unit manually (See MAINTENANCE; 
DEFROSTING).
Door gasket not sealing properly
Adjust door (See MAINTENANCE; DOOR ALIGNMENT 
CHECK AND ADJUSTMENT and DOOR REVERSAL).
Item(s) interfering with door
Reposition or remove item(s).
Noise during operation
Copper water supply tubing 
contacting internal components
Carefully bend tubing away from cabinet and 
components.
Refrigerator too cold
Temperature control set too cold
Set control to warmer setting (See OPERATION).
Inaccurate temperature reading
Properly check temperature (See OPERATION).