4  Refrigeration, Plumbing & Electrical Procedures 
4.1    Piping (Plumbing, Refrigeration) 
 ●    U-trap installation 
Install U-trap referring to the drawing below. 
                             
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
●  Sealing the refrigerant pipe opening 
Seal pipe completely. 
Insufficient sealing may cause the following problems: 
• 
Insufficient cooling 
• 
Excessive frost 
• 
Icing over 
• 
Condensation on the bottom of case.       
 
Part Name 
Part Number 
①  Drain Screen 
845-0-1962-001-00 
②  O-Ring 
845-2-6946-001-00 
③  Drain Trap Socket 
845-2-6959-003-00 
④  Drain Trap 
845-2-1437-103-00 
⑤  O-Ring 
845-2-0183-107-00 
⑥  Drain Cap 
845-2-1345-110-00