4 Refrigeration, Plumbing & Electrical Procedures
4.1 Piping (Plumbing, Refrigeration)
● U-trap installation
Install U-trap referring to the drawing below.
● Sealing the refrigerant pipe opening
Seal pipe completely.
Insufficient sealing may cause the following problems:
•
Insufficient cooling
•
Excessive frost
•
Icing over
•
Condensation on the bottom of case.
Part Name
Part Number
① Drain Screen
845-0-1962-001-00
② O-Ring
845-2-6946-001-00
③ Drain Trap Socket
845-2-6959-003-00
④ Drain Trap
845-2-1437-103-00
⑤ O-Ring
845-2-0183-107-00
⑥ Drain Cap
845-2-1345-110-00