Fujitsu MAN3735 Manuale Utente

Pagina di 302
C141-E124-01EN
3 - 42
a.
In the case of the start specification ("Start" bit = "1")
When the "Immed" bit is "1," simply by instructing starting of the spindle motor, a
GOOD status is reported without waiting until the disk drive is in the Ready state, and
command execution is completed.
When the "Immed" bit is "0," the status byte is reported, and command execution is
completed, at the point when the disk drive has entered the Ready state after the spindle
motor has started.
b. In the case of the stop specification ("Start" bit = "0")
When the "Immed" bit is "1," simply by instructing stopping of the spindle motor, the
GOOD status is reported and command execution is completed.
When the "Immed" bit is "0," the status byte is reported, and command execution is
completed, after the spindle motor is in the stopped state.
Notes:
1.
When this command with the Start instruction is issued with a link to another command,
the specification in the "Immed" bit should be "0."  If "1" is specified for the "Immed" bit,
ordinarily, the disk drive is still not in the Ready state at the point when this command is
completed, so a linked command cannot be executed normally
2.
Even if "1" is specified in the "Immed" bit of this command, if other commands are
already queued and another command exists which is already being executed, this
command is placed on the queue and disconnect processing is performed.  Therefore,
even if "1" is specified in the "Immed" bit, the status will not necessarily be reported
immediately after the COMMAND phase.