Fujitsu MAN3735 Manuale Utente

Pagina di 302
C141-E124-01EN
3 - 85
When access to logical data blocks outside the address range defined by this command by linked
commands which follow this command is specified, or when a prohibited type of access operation
is specified, that command is terminated with a CHECK CONDITION status without being
executed.  (When there is a violation of the (DATA PROTECT [=7] / Write protect [=27-00]:
"WrInh" flag, or when there is a violation of the (DATA PROTECT [=7] / No additional sense
information [=00-00]: "RdInh" flag.)  When this command is issued again in a group of commands
linked in a series, the 2nd SET LIMITS command is rejected and a CHECK CONDITION status
(DATA PROTECT [=7] / Command sequence error [=2C-00]) is reported.
Notes:
1.
Commands which come under restrictions in read operations or write operations when "1"
is specified in the "RdInh" (read inhibit) or "WrInh" (write inhibit) flag are as follows.
“RdInh”
x  READ
x  VERIFY (*)
x  READ EXTENDED (*)
x WRITE AND VERIFY (*)
x  READ LONG
x  PRE-FETCH
“WrInh”
x  FORMAT UNIT
x WRITE EXTENDED (*)
x  REASSIGN BLOCKS
x  WRITE LONG
x  WRITE
x  WRITE SAME
x  WRITE AND VERIFY (*)
*
When zero is specified in the processing block count, that command is not executed.
2.
Even if a write operation is prohibited by this command, "0" is indicated in the "WP
(write protect)" bit reported to the INIT in the MODE SENSE and MODE SENSE
EXTENDED commands.
3.
If "0" is specified in this command in the "WrInh" flag, execution of a FORMAT UNIT
command or REASSIGN BLOCKS command issued in linked form following this
command is permitted (the specification of the range where access is permitted is not
applied.)