Air Flow
NOTICE
The unit requires proper air flow to perform at its highest 
efficiency. Do not block the front grille or internal fans at 
any time, or the unit will not perform as expected. Do not 
install the unit behind a door.
Initial Startup
All U-Line controls are preset at the factory. Initial startup requires 
no adjustments. 
NOTICE
U-Line recommends allowing the unit to run overnight 
before loading refrigerator or freezer with product.
To turn the unit on or off, press and hold the POWER icon (1) for 
about ten seconds and release. The display will show the unit set-
point temperature on Combo models, and ICE on Clear Ice 
models when turned on and display “OFF” when the unit is off. 
Electronic Control Panel
Digital Display. The electronic control with digital display on 
Combo models shows a single continuous set-point temperature, 
or on Clear Ice models it shows “ICE”. The set point is for the 
middle zone, it is a base number used by the controller to maintain 
the multiple temperature zones in the unit. The factory default set-
point for Refrigerator models is 38°F. The set-point temperature is 
a gauge for further temperature adjustments.
Adjusting Air Temperature 
CLRCO2175
NOTICE
Adjust the set point temperature in single increments, 
and wait 24 hours for the temperature to stabilize before 
rechecking.
Note: The CLRCO2175 refrigerator zone temperature is adjustable. The 
ice storage bin temperature in the CLRCO2175 or CLR2160 is not 
adjustable.
To adjust the set point temperature:
1. Press and release either WARMER 
 (2) or COOLER 
 (4) 
to put the controller in the SET TEMPERATURE mode. The 
display (3) will begin to flash the °F (or °C) symbol.
NOTE: This mode will self-cancel in five seconds, and the 
display (3) will show the original set point temperature.
2. Within five seconds (while the °F (or °C) symbol is flashing), 
press WARMER 
 or COOLER 
 as required to adjust the 
set point temperature.
3. The change sets five seconds after adjusting the temperature, 
and the display (3) will show the new set point temperature.
Temperature °F °C Selection. U-Line products supplied for 
110 VAC have temperatures displayed (3) by default in Fahrenheit 
(°F). Models supplied for 220 VAC have temperatures displayed (3) 
by default in Celsius (°C).
Easily adjust the display for either type temperature display. 
1. Press and hold LIGHT 
 (1) and simultaneously within five 
seconds press COOLER 
 (5) three times to change the 
display (3) as needed.
Temperature Display. The digital display shows set-point. air 
temperature. Under normal operating conditions the temperature 
will fluctuate based on a number of factors including door 
openings, product load, room temperature, and humidity. The 
temperature will always be cool toward the top and coolest 
toward the bottom. 
To display actual temperature:
1. Press WARMER 
 (2) for five seconds. The display (3) will 
indicate the actual temperature.
2. After about 10 seconds, the set point temperature will return to 
the display.