Guardian Technologies PTDCM (SA12020) Manuale Utente

Pagina di 4
¬19=l
N8724V1 
 5/00
DCM Connections
11 12 13 14 15 16 17 18 19 20
J1
BATTERY SUPERVISION
AC SUPERVISION
GROUND
+14VDC MAX.
DCM
TO MLB TERM. 15
TO MLB TERM. 16
GROUND (SE NOTE)
GROUND (SE NOTE)
DATA IN (WHITE)
LEDRDRA (SEE NOTE)
GROUND (BLK)
DATA OUT (CLOCK) GRN
FROM PS
CONNECTOR J5
}
TO CARD READER A
TO CARD
READER B
NOTE:  Ground terminals are 
common and may be used if
connecting to a module that
requires a power or signal
return line.
NOTE:  Use orange lead for GREEN LED signal (LEDRDRA or 
LEDRDRB) on some HID readers.  All other readers use brown
lead.  Check the label on your reader for proper GREEN LED 
connection.  Connect reader(s) to 5V or 12V per manufacturer's
voltage specification.
GROUND
+12VDC
GROUND (SEE NOTE)
LOGIC POWER IN
BATTERY SUPERVISION
AC SUPERVISION
+5VDC
TRIGGER A
TRIGGER B
+12VDC
GROUND (SEE NOTE)
40 39 38 37 36 35 34 33 32 31
30 29 28 27 26 25 24 23 22 21
ZONE B
ZONE A
GROUND
1
2
3
4
5
6
7
8
9
10
2000
OHMS
EOLR
(RTE)
2000
OHMS
EOLR
(DSM)
ZONE D
ZONE C
GROUND
2000
OHMS
EOLR
(RTE)
2000
OHMS
EOLR
(DSM)
TWISTED PAIR,
TERMINATED
OPTIONAL
DATB 0 (Clock) (GRN)
DATB 1 (Data) (WHT)
LEDRDRB (See Note)
GROUND (BLK)
+5VDC
+12VDC
DOOR B RELAY SUPERVISION
DOOR B DOOR STRIKE (N.O.)
DOOR B RELAY COMMON
DOOR B MAG HOLD (N.C.)
TO MAG LOCK
TO PS TERM 7
TO DOOR STRIKE
GROUND (SEE NOTE)
DOOR A RELAY SUPERVISION
DOOR A STRIKE (N.O.)
DOOR A RELAY COMMON
DOOR A MAG HOLD (N.C.)
TO MAG LOCK
TO PS TERM 7
TO DOOR STRIKE
RELAY CONTACT
CONNECTIONS
NOT TO EXCEED
28V @ 5A
(RESISTIVE LOADS)
NOTE: USE APPROPRIATE
TRANSIENT SUPPRESSION
ON DOOR LOCK DEVICES.
DCM LEDs
Red:
On when associated relay is energized.
Yellow: Blinks for 1 second during enrollment process.  If this LED blinks or is on at any other
time, there is a hardware problem.  However, expect this LED to blink briefly when
power is applied.
Green:
Three blinks = OK.  Any other pattern indicates hardware problem.
Enrolling and Configuring the DCM
Once the DCM has been mounted and connected, it needs to be enrolled into the system and
configured.  Refer to the PassPoint Express Installation and Setup Guide (N8949) or the
PassPoint Plus Installation and Setup Guide (K4879) for information on enrolling and
configuring Door Control Modules.
Warranty Information
For complete warranty information, refer to the documentation accompanying your system.
5007 South Howell Avenue
Milwaukee, WI 53207
www.nciaccess.com
Copyright © 2000 PITTWAY CORPORATION