Mounting
flange
dRAWER INStALLAtIoN
1.   Place the drawer adjacent to the wall or 
cabinet opening. Plug the power supply cord  
into the electrical outlet. 
2.   Carefully guide the drawer into the prepared 
opening. Avoid pinching the cord between 
the oven and the wall. 
3.   Slide the drawer all the way until the 
mounting flange is flush with the face of the cabinet. See
Figure 8A.
4.   Open the drawer. Using the 4 holes on the drawer as a template, 
pre drill the cabinet using a 1/16" bit. See Figure 8A.
5.   Secure the drawer with the 4 screws supplied. See Figure 8B.
modEL ANd SERIAL NUmBER LoCAtIoN
The name plate includes model and serial number. Open the 
Microwave Drawer fully. The label is beyond the back wall of 
the microwave cavity facing up from the flat surface.
CARE, CLEANING ANd mAINtENANCE
Refer to the Operation Manual for cleaning instructions.
BEfoRE yoU CALL foR SERvICE
Read the BEFORE YOU CALL and operating instruction sections
in your Operation Manual. It may save you time and expense. 
The list includes common occurrences that are not the result of 
defective workmanship or materials in this appliance. 
Refer to the warranty in your Operation Manual for Sharp’s 
service number and address. Please call or write if you have 
inquiries about your microwave product and/or need to order 
parts.
Figure 8A 
ELECtRICAL oUtLEt
4"
(101.6 mm)
5" (127 mm)
6"
(152.4 mm)
3 1/2"
(89 mm)
Suggested electrical
outlet location*
Anti-Tip block
The  electrical  requirements  are  a  120  volt  60  Hz,  AC  only,                
15 amp. or more protected electrical supply. It is recommended 
that a separate circuit serving only this appliance be provided.
The drawer is equipped with a 3-prong grounding plug. It must 
be plugged into a wall receptacle that is properly installed and 
grounded. Should you only have a 2-prong outlet, have a qualified
electrician install a correct wall receptacle.
Note: If you have any questions about the grounding or electrical 
instructions, consult a qualified electrician or service person.
*  Can also be installed using an electrical outlet in an adjacent cabinet 
within the area where the provided electrical cord can reach.
  Always check electrical codes for requirements.
GRoUNdING INStRUCtIoNS
This appliance must be grounded. The Microwave Drawer is 
equipped with a cord having a grounding wire with a grounding 
plug. It must be plugged into a wall receptacle that is properly 
installed  and  grounded  in  accordance  with  the  National        
Electrical Code and local codes 
and ordinances. In the event of 
an electrical short circuit, 
grounding reduces risk of 
electric shock by providing an 
escape wire for the electric 
current.
 – Improper use 
of the grounding plug can result 
in a risk of electric shock. Do 
not use an extension cord. If 
the power supply cord is too short, have a qualified electrician 
or serviceman install an outlet near the appliance.
Figure 7
3-Prong plug
Grounding pin
3-Prong receptacle
Grounded receptacle box
Grounding adapter
Grounded receptacle box
Screw
Tab for grounding screw
4 Screws
Parts supplied
Figure 8B
SHARP ELECTRONICS OF CANADA LTD
335 Britannia Road East • Mississauga, Ontario • L4Z 1W9