supply connection(s).  Provide 24" clearance at the front for cleaning, maintenance, 
service and proper operation.   
Minimum clearances to combustible construction are 12" to the back and 9" to the sides. 
Minimum clearances to non-combustible walls are 0" to the rear and 0" to the sides. 
INSTALLATION CODES AND STANDARDS 
The Charbroiler must be installed in accordance with: 
In the United States of America: 
1.  State and local codes. 
2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but 
not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained 
from The American Gas Association Accredited Standards Committee Z223,  @ 400 
N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 
1 Batterymarch Park Quincy, MA 02169-7471  
 
NOTE: In the Commonwealth of Massachusetts 
 
All gas appliances vented through a ventilation hood or exhaust system equipped with 
a damper or with a power means of exhaust shall comply with 248 CMR. 
3.  NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available 
from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. 
In Canada: 
1. Local codes. 
2.  CAN/CSA-B149.1 Natural Gas Installation (latest edition)   
3.  CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the 
Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3 
   
BURNERS, RADIANTS, AND TOP GRATES 
The top grates are shipped flat (top-side 
down) from the factory for stock pot use.  
For broiling, the top grates can be left in 
the flat position or reversed so they slope 
forward for grease run-off.  Remove the 
cast iron radiants (Fig. 1) and inspect and 
remove the shipping tape used during 
shipping to hold the burners in place.  
Reassemble the radiants and the top 
grates. Unpack the supercharger burner 
dividers and install between burners.  The 
tabs on the superchargers should be 
inserted in the slots at the front of the fire 
box.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Burners 
Radiants
Top Grate
        Supercharger Burner Dividers 
Fig. 1