Smeg A1-6 Manuale Utente

Pagina di 31
 
Instructions for the installer
 
 
 
 
 
 
 
The manufacturer declines all responsibility for damage to persons 
or things caused by non-observance of the above prescriptions or by 
interference with any part of the appliance. 
 
2.2   
2.3  Ventilation requirements 
 
 
The room containing the appliance should have an air supply in 
accordance with B.S. 5440 part 2 1989. 
1.
 
All rooms require an opening window or equivalent, and some 
rooms will require a permanent vent as well. 
2.
 
For room volumes up to 5 m
3
 an air vent of 100 cm
2
 is required. 
3.
 
If the room has a door that opens directly to the outside, and the 
room exceeds 1 m
3
 no air vent is required. 
4.
 
For room volumes between 5 m
3
 and 10 m
3
 an air vent of 50 cm
2
 is 
required. 
5.
 
If there are other fuel burning appliances in the same room B.S. 
5440 part 2 1989 should be consulted to determine the air vent 
requirements. 
6.
 
This appliance must not be installed in a bed sitting room of less 
than 20 m
3
 or in a bathroom or shower room. 
Windows and permanent vents should therefore not be blocked or 
removed without first consulting a Corgi gas installer. 
Failure to install appliances correctly is dangerous and could lead 
to prosecution.
 
2.4   
2.5  Connecting to natural and LPG gas (Please see 
connection diagram) 
 
This type of connection is possible on both built-in and 
free-standing appliances. Make the connection to the 
appliance using flexible bayonet style hose in 
accordance to B.S. 669. The hose connection at the 
rear of the appliance has a ½” BSP internal thread. 
Please use seal C between the flexible connection L
and the appliance supply tube B
After completing the installation, check for any 
leaks with a soapy solution, never with a naked 
flame
. Make sure that the hose complies with the 
regulations in force. 
When connecting to an LPG cylinder use a pipe with 
adapter for connection to the pressure regulator. 
If connecting to LPG the bayonet hose must have 
red bands on it. 
Take care that the hose is not crushed or damaged. 
39