Installation
WARNING – THIS APPLIANCE MUST BE EARTHED.
Mains Connection
Your cooker should have been checked to ensure that the voltage corresponds with your
supply voltage, this is stated on the rating plate, which is situated on the outer rear panel.
The model number and serial number are located on the front of the cooker, as shown on
the Feature’s page.
The cooker must be connected by a competent person such as one who is a, NICEIC registered
contractor  to a suitable double-pole control unit with a minimum rating of 32A and a minimum
contact clearance of 3mm (applicable to newer properties, older properties where a 30A
double pole control unit and a minimum contact clearance of 3mm is acceptable).
The double pole control unit should be fitted adjacent to the cooker, in accordance with
IEE  regulations. The  control  unit  must  be  within  2  metres  of but  not  directly  above  the
appliance and should be easily accessible in the event of an emergency.
The power supply cable should conform to B.S.6004 with a conductor size of 6mm
2
, minimum.
Access  to  the  mains  terminals  is  gained  by  removing  the  rear  access  cover. The  mains
cable must pass through the cable clamp adjacent to the terminal block. Sufficient cable
should be used to allow the cooker to be pulled out for servicing.
Ensure that the mains cable is routed away from any brackets affixed to the rear panel
and is not trapped to the rear wall when pushing the cooker into position between cabinets.
Levelling
Four feet are fitted which can be adjusted up or down to set the height (900mm - 930mm)
and level the cooker.
The feet can be simply screwed in or out to lower or raise the cooker.
After the correct height is achieved, lock the feet into position by tightening the locking nut
using an open ended spanner.
CAUTION:
Some soft floor coverings may get damaged if the cooker is not moved carefully.
NOTE:
Ensure oven shelves are level by using a spirit level on the rod shelves.
Siting the Cooker
The cooker is designed to fit between kitchen cabinets spaced 600mm apart. The space
either side need only be sufficient to allow withdrawal of the cooker for servicing. It can be
used with cabinets one side or both as well as in an angled  corner setting. It can also be
used freestanding.
Adjacent side walls which project above hob level, must not be nearer to the cooker than
150mm  and  should  be  protected  by  heat  resistant  material. Any  overhanging surface  or
cooker hood should not be nearer than 650mm.
Note: This appliance must NOT be fitted on a platform.
Moving the Cooker
Before moving your cooker, switch off at the cooker control unit, ensure that it is cool.
Open the grill door sufficiently to allow a comfortable grip on the underside front edge of
the oven roof, avoiding any grill elements.
Radio Interference
This appliance conforms to EN 55014 regarding suppression of radio and television 
interference.
Note: Take  care  in  moving  the  cooker  as  it  is  heavy. Take  care  to  ensure  that  any  floor
covering is not damaged.