Desa CGESBMR Manuale Utente

Pagina di 12
www.desatech.com
117190-01B
3
SAFETY INFORMATION
Continued
12.  Always disconnect the unit from the power 
supply before performing any cleaning, light 
bulb replacement, maintenance, relocating the 
heater or when the unit is not in use for long 
periods of time.
13.  When transporting or storing the unit, keep 
it in a dry location, free from dust, excessive 
vibration or other factors, which may damage 
the unit. 
LISTING APPROVALS
This heater has been tested in accordance with the 
CSA Standards for fixed and location-dedicated 
electric room heaters in the United States. All 
components are UL or CSA safety certified.
If you need assistance during installation, please con-
tact your local dealer or the DESA Heating Products 
Technical Services Department at 1-866-672-6040.
UNPACKING AND 
TESTING THE UNIT
Carefully remove the unit from the box. Prior to 
permanently installing the unit, test to make sure 
the unit operates properly by plugging the power 
supply cord into a conveniently located 120-volt 
grounded outlet.
 CAUTION: The unit's power 
supply cord must be connected 
to a properly grounded and pro-
tected  120-volt  outlet.  Always 
use  ground  fault  protection 
where  required  by  the  electri-
cal code.
  WARNING:  Do  not  operate 
the  unit  if  it  is  damaged  or  has 
malfunctioned . If you suspect the 
unit is damaged, return the unit 
to an authorized service facility 
for examination, electrical or me-
chanical adjustment or repair.
Frequency 
60 Hz
Heater Power  1500 W
Heater Output  5000 BTUs
Power Supply  120V; 15 Amp 
 
Grounded, Circuit
PRODUCT DIMENSIONS & 
SPECIFICATIONS
Figure 1 - Heater Dimensions
Note: 
A dedicated power supply circuit is recom-
mended for the unit but not required. Additional 
electrical appliances on the same circuit may ex-
ceed the current (amperage) rating for that circuit. 
If after the installation of your unit, the circuit 
breaker trips or the fuse fails on a repeated basis, 
then a dedicated circuit will likely be required. Any 
new wiring must be done in compliance with local 
and national codes and other applicable regula-
tions in order to reduce the risk of fire, electric 
shock or other injuries. Therefore, it is strongly 
recommended that you hire a licensed electrician 
to complete any such work.
27"
15"
26"
12.5"
25.25"
18"
CGESBMR/VESBMR Remote Controlled  
18" Electric Stove
CGESBL/VESBL Remote Controlled  
27" Electric Stove