The electrical protection system must be subjected to a functional test before use. The installation must be 
performed and/or verified by the authorized reseller who will be responsible for the first startup and the 
instructions relative to the dishwasher’s operation. 
 
PREPARATION FOR USE 
Important: 
The rinse-aid metering unit comes equipped in all models 
while the detergent metering unit comes equipped in only 
some models. 
If both metering units are present
 position the external 
detergent and rinse-aid containers and insert their 
respective suction tubes located at the back of the machine. 
Red tube: detergent 
Transparent tube: rinse-aid 
Before inserting the tubes in the containers apply the weight 
(necessary to keep the tube at the bottom of the container) 
and the filter as indicated in the diagram. 
 
For adjustments, use the adjustment screws indicated in the diagram. It is 
recommended that adjustments be performed by personnel from the companies who 
have supplied the detergent products. 
If the detergent metering unit did not come pre-installed it can be installed at a later 
time by ordering the relative KIT. 
 
Alternatively, an external metering unit can be connected by means of an electrical 
connection with a 2x0.5 mm type H05 RN-F cable. This cable must be inserted through 
the passage indicated in the TECHNICAL CHARACTERISTICS scheme and 
connected in accordance with the electrical scheme furnished with the dishwasher. 
The metering unit must be of 230V/50Hz with a maximum absorbed power of 15W
Connect the detergent metering unit to the dishwasher through the red tube cited above. 
SETTINGS (only models CW400RSD - CW400R – CWC500R) 
 
 
POWER SUPPLY: 200 – 250 VAC. 
ABSORBED POWER : 4 VA 
OPERATIONAL TEMPERATURE: 0 / 60 °C 
OPERATIONAL HUMIDITY: max 90 % without condensation 
NORMS: The control unit is designed and manufactured in observance of the  
European norms in vigor regarding electrical safety and electromagnetic compatibility. 
Particularly the following: 
 
EN 61000-6-3 : Emissions for residential and commercial environments 
EN 61000-6-2 : Immunity for industrial environments 
EN 61000-4-11 : Immunity to supply micro-interruptions 
EN 60335-1 : Low voltage safety directive 
back of the machine. 
‐  The protection conductor (PE) is yellow-green in color, the neutral conductor (N) is blue and the 
phase conductors (L1, L2, L3) are black, gray and brown. 
 
 
 
 
 
 
SETTINGS 
During the first startup, arrange for the setup or the adjustment of the functions/parameters indicated 
hereafter: