Cornelius DF/ED250PRO Manuale Utente

Pagina di 5
Installation Instructions for DF/ED250PRO Field Kit
© 2002, IMI Cornelius Inc.
- 1 -
Publication Number: 620919569
INSTALLATION INSTRUCTIONS
DF/ED250PRO F
IELD
 K
IT
 (P/N 629087544)
Installation of Low CO2 Indicator Light
CAUTION:  Disconnect electrical power to the dispenser before proceeding with the 
CO2 indicator light installation.
CAUTION:  The Beverage System (water and CO2) must be depressurized and drained 
before proceeding with the installation.
1. Remove the upper front panel which is secured to the cabinet by “hooks” that fit into slots 
on the cabinet front flange.  Lift up on the panel right and left sides to disengage the hooks 
from the slots and then rotate the panel downward and forward to remove from the cabinet.  
Disconnect the (3) electrical harnesses at the rear of the front panel.
2. Remove the lower front splash panel (2 screws).
3. Locate the CO2 supply line (1/4 beverage tubing) to the carbonator tank located on the 
right side of the unit above the coldplate (see Fig. 1).  Cut this line in an area that will be 
accessible for future servicing and install the CO2 pressure switch with the fittings provided in 
the kit (see Fig. 3).
4. Refer to Fig. 2 for installing the CO2 indicator light on the upper front panel.  Remove the 
lid and straw holder by loosening (3) screws at the “key-holes” and lifting up to clear the screw 
heads.  Remove the lower front ice portion control enclosure (4 screws) and disconnect the 
electrical harnesses as needed for reworking the enclosure.  Locate and drill a 1/2 in. diame-
ter hole in the enclosure as shown in Fig. 2 for the indicator light.  Insert the light from the 
front and “snap” into the mounting hole.
5. Refer to the wiring detail of Fig. 4 to complete the electrical hook-up of the indicator light to 
the pressure switch and the 24V beverage transformer power source.
6. Route the electrical wires to the CO2 pressure switch behind the beverage panel with the 
harnesses from the unit’s electrical control box.  Remove the (6) screws securing the bever-
Parts List
Item No.
Part Number
Description
Qty.
1
620313223
CO2 Pressure Switch
1
2
77060500
Tee 1/4MFL
1
3
40502
O-Clamp
2
4
77010400
1/4 Barb Stem
2
5
77045700
1/4 Flare Swivel Nut
2
6
178025100
1/4 Flare Washer
3
7
33666
Indicator Light 24V
1
8
620316401
CO2 Light Harness
1
9
620316402
CO2 Pressure Switch Harness
1
10
620313651
Jumper CO2 Pressure Switch
1
11
32870
Splice
2
12
50705
Cable Tie
8
13
620920638
Label Low CO2 Light
1
14
620919569
Installation Instructions
1
Release Date: October 9, 2002
Revision: A