ELECTRICAL REQUIREMENTS AND SAFETY
or a #14 wire with a 15 A time-lag fuse. 
NOTE: When 
using an extension cord on a circuit with a #14 wire, the 
extension cord must not exceed 25 feet in length. Before 
connecting the motor to the power line, make sure the 
switch is in the OFF (O) position and the electric current 
is rated the same as the current stamped on the motor 
nameplate. Running at a lower voltage will damage the 
motor. This tool is intended for use on a circuit that has 
a receptacle like the one illustrated in Fig. 1.
Fig. 1 shows a three-pronged electrical plug and 
receptacle that has a grounding conductor. If a properly 
grounded receptacle is not available, an adapter (Fig. 2) 
can be used to temporarily connect this plug to a two-
contact grounded receptacle. The adapter (Fig. 2) has a 
rigid lug extending from it that MUST be connected to a 
permanent earth ground, such as a properly grounded 
receptacle box. 
WARNING
In all cases, make certain the receptacle is properly 
grounded. If you are not sure, have a qualified 
electrician check the receptacle.
WARNING
This tool is for indoor use only. Do not expose to 
rain or use in damp locations.
Fig. 1       
   
                             
Fig. 2
CAUTION
This tool must be grounded while in use to protect 
the operator from electric shock.
MINIMUM GAUGE FOR EXTENSION CORDS (AWG)
(When using 120 volts only)
Ampere Rating 
Total length of Cord
More Than
           
Not More Than
       25ft.    50ft.     100ft.    150ft.          
0                         6
18       16        16         14     
6                        10  
18       16        14         12     
10                      12
16       16        14         12     
12                      16
14       12       
Not Recommended
     
GROUNDING INSTRUCTIONS
IN THE EVENT OF A MALFUNCTION OR 
BREAKDOWN, grounding provides a path of least 
resistance for electric currents and reduces the risk of 
electric shock. This tool is equipped with an electrical 
cord that has an equipment-grounding conductor 
and a grounding plug. The plug must be plugged 
into a matching receptacle that is properly installed 
and grounded in accordance with all local codes and 
ordinances.
DO NOT MODIFY THE PLUG PROVIDED. If it will not 
fit the receptacle, have the proper receptacle installed 
by a qualified electrician.
IMPROPER CONNECTION of the equipment grounding 
conductor can result in risk of electric shock. The 
conductor with the green insulation (with or without 
yellow stripes) is the equipment grounding conductor. 
If repair or replacement of the electrical cord or plug is 
necessary, do not connect the equipment grounding 
conductor to a live terminal.
CHECK with a qualified electrician or service person 
if you do not completely understand the grounding 
instructions, or if you are not certain the tool is properly 
grounded.
USE only three-wire extension cords that have three-
pronged grounding plugs with three-pole receptacles 
that accept the tool’s plug. Repair or replace damaged 
or worn cords immediately.
GUIDELINES FOR EXTENSION CORDS
USE THE PROPER EXTENSION CORD. Make sure 
your extension cord is in good condition. Use an 
extension cord heavy enough to carry the current your 
product will draw. An undersized cord will cause a drop 
in line voltage resulting in loss of power, 
overheating and burning out of the motor. The table on 
the right shows the correct size to use depending on 
cord length and nameplate ampere rating. If in doubt, 
use the next heavier gauge. The smaller the gauge 
number, the heavier the cord.
Make sure your extension cord is properly wired and in 
good condition. Always replace a damaged extension 
cord or have it repaired by a qualified technician before 
using it. Protect your extension cords from sharp 
objects, excessive heat and damp or wet areas. 
Use a separate electrical circuit for your tool. This circuit 
must not be less than #12 wire with a 20 A time-lag fuse 
Three-Pronged Plug
Grounding Prong
Properly Grounded
Three-Pronged Receptacle
Grounding Lug
Make sure this is 
connected to a 
known ground.
Two-Pronged 
Receptacle
Adapter