13. Connection to Camera Head (IK-M43H/IK-C43H)
When connecting to the camera head (IK-M43H/IK-C43H), select the internal switch inside
the camera controller following to the procedures below.
1 After turning off the power, remove all the
cables connected to the camera control-
ler.
2 Remove three screws on the bottom chas-
sis of the camera control unit to remove
the internal unit.
3 Turn off No. 3 of S101 switch located on
the component side of the internal circuit
unit PC board.
No3 of S101
switch
OFF
ON
Applicable camera
 head to connect
IK-M43H
IK-CN43H
IK-M44H
IK-C44H
IK-UM44H
IK-SM44H
IK-SM45H
Note: Do  not change the switch settings
other than S101. If you change the set-
tings, the normal image may not be
obtained.
4 Perform the reverse procedures to as-
semble.
H101
S101
Q503
Q508
P101
ON
OFF
Servicing Instructions for
Service Personnel
Front Side