NCR S10 Manuale Utente

Pagina di 200
Error Messages
System Error Messages
NCR S10 Desktop Server User Guide
B-3
System Error Messages
A system error message indicates a problem with the
computer itself. A message of this type normally
appears during the power-on self-test, before the
operating system prompt appears.
Table B-1 lists system error messages and the
corresponding corrective measures.
Table B-1
Error Messages
Message
Action
CMOS battery error
Replace the RTC chip or contact your dealer.
CMOS Checksum Error
Check the RTC chip and the necessary jumper. If the
battery is still good, run Setup.
Display card mismatch
Run Setup.
Diskette drive error
Diskette may be bad. If not, replace the diskette drive
or cable.
Diskette drive controller error or
not installed
Check and connect the control cable to the diskette
controller.
Diskette drive A type mismatch
Run Setup and select the proper drive type.
Diskette drive B type mismatch
Run Setup and select the proper drive type.