Q-Logic 8C Manuale Utente

Pagina di 162
59042-01 A
5-1
Section 5
Diagnostics/Troubleshooting
Diagnostic information about the switch is available through the chassis LEDs and 
the port LEDs. Diagnostic information is also available through the SANbox 
Manager and CLI event logs and error displays. This section describes two types 
of diagnostics: Power On Self Test (POST) and chassis. POST diagnostics 
describe the Heartbeat LED and the port Logged-In LED indications. Chassis 
diagnostics cover power supply and fan diagnostics as well as over temperature 
conditions. This section also describes how to use force PROM mode to recover a 
disabled switch.
5.1
POST Diagnostics
The switch performs a series of Power On Self Tests (POST) as part of its 
power-up procedure. The POST diagnostic program performs the following tests:
Checksum tests on the boot firmware in PROM and the switch firmware in 
flash memory
Internal data loopback test on all ports
Access and integrity test on the ASIC
During the POST, the switch logs any errors encountered. Some POST errors are 
fatal, others are non-fatal. The switch uses the Heartbeat LED and the Logged-In 
LED to indicate switch and port status. A fatal error disables the switch so that it 
will not operate. A non-fatal error allows the switch to operate, but disables the 
ports that have errors. Whether the problem is fatal or non-fatal, contact your 
authorized maintenance provider.
If there are no errors, the Heartbeat LED blinks at a steady rate of once per 
second. If a fatal error occurs, the Heartbeat LED will show an error blink pattern. 
If there are non-fatal errors, the switch disables the failed ports and flashes the 
associated Logged-In LEDs. Refer to 
 
for more information about Heartbeat LED blink patterns.
5.1.1
Heartbeat LED Blink Patterns
5.1.1.1
Normal (all pass)
If all POST diagnostics pass, the switch will go to normal operation and the 
Heartbeat LED will blink at a steady rate of one (1) blink per second.