Q-Logic MKII-BASE16 Manuale Utente

Pagina di 138
1-10
General Description
GigWorks MKII-16 Switch Model MKII-BASE16
59003-01 Rev. A            Installer's/User's Manual 
General Description
time or several times over a short period of time when they are powered up.
If the Switch was not operable at that time, it would miss this login attempt
and the attached node may give up trying and require rebooting after the
Switch becomes operable.
Port  Activity LED (Yellow)
Each port has its own Port Activity LED. The Port Activity LED for a particular
port is ON when Class 1, 2, or 3 frames are entering or leaving the port. The
Switch turns the LED ON for 50 msec. for each frame, so you should be able to
see it for one frame. This LED will not light for frames following an arbitrated
loop in bypass mode.
Chassis Back
Refer to Figure 1-4.
Figure 1-4  Chassis Back
AC Input Power Connector and Fuses
A standard 3-wire computer-type AC power cable (supplied with the Switch)
connects between the AC Input Power Connector and an AC outlet. Refer to the
Reference Information for the AC Power Requirements. See also Section 2 for
installation procedures.
Switch 
Management 
Connector
(Ethernet)
(RJ45)
Power Supply
Optional second Power Supply
AC Power 
Input Connector
Input 
Fuses (2)
Fan
(The Fan is part of the Power Supply. 
Air enters the front of the chassis and 
exits the back of the chassis.)
Finger Pulls (2)
Power Supply
Locking Screws (2)
Power Good Light
(Green)
Overheat Light
(Red)
Cover
Plate
(if no second 
Power Supply)
Chassis Switch Panel
(Behind Cover Plate)