Cabletron Systems SmartCell 6A000 Manuale Utente

Pagina di 102
4-16   SmartCell 6A000 User Guide
Setting Up PVC Connections
  Switch Administration
3.
Use 
add pvc
 to successively create point-to-multipoint PVCs for ports B2, B3, and C1.
SmartCell ZX # add pvc
ConnType(PTP)                             : pmp 
<specify point-to-multipoint
LowPort(A1)                               : 
<port connected to broadcast workstation
LowVPI(0)                                 :
LowVCI(33)                                : 100
HighPort(A1)                              : b2 
<port connected to first receiver workstation
HighVPI(0)                                :
HighVCI(34)                               : 100
FwdTrafficDescriptorIndex(1)              :
BkwTrafficDescriptorIndex(1)              : 
<Index of Traffic Descriptor with AALType = 0
SmartCell ZX #
Perform step 3 for ports B3 and C1.
4.
Connect the workstations to their respective ports.
5.
Configure the workstations with the same subnet and VPI/VCI pair.
The broadcasting workstation on port A1 can send traffic to the receiving workstations on ports B2, B3, and C1.
4.5.3
Non-zero VPIs
The SmartCell 6A000 uses 12 bits to define VPI/VCI pairs.
 vccmask
 determines how many of the 12 bits are used for 
the VPI and how many are used for the VCI. 
vccmask
 uses a 2-bit register to hold four different VPI/VCI 12-bit 
combinations. Table 4-1 shows the registers and the values that come preconfigured on the SmartCell 6A000.
Use the
 show vccmask
 command to view the four preconfigured VPI/VCI combinations.
SmartCell ZX # show vccmask
MaskIndex   VpiShift     VciShift
           (In bits)     (In bits)
============================================================================
  0          0            12 
  1          2            10 
  2          4            8 
  3          6            6 
SmartCell ZX #
VCCMask combinations dictate what numerical values can be used for VPI/VCI pairs. Any VPI and VCI pairs that fit 
the bit distribution of one of the indexed combinations can be used for defining a PVC. If the VPI and VCI values do 
not fit one of the indexed combinations, the SmartCell 6A000 uses the closest matching indexed combination.
If you need to use values for VPI and VCI that do not fall within the range of one of the preconfigured indexed 
combinations, use the
 set vccmask 
command to replace one of the preconfigured combinations. 
Table 4-1
Values for VPI and VCI
VCC Index
VPI Bits
VPI Values
VCI Bits
VCI Values
0
0
0
12
0  to  4095
1
2
0 to 3
10
0 to 1023
2
4
0 to 15
8
0 to 255
3
6
0 to 63
6
0 to 63