Chapter 5: Local Management
5-32
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Source Port [
n] (Selectable)
Allows a selected port [n] to be configured as a source port.
Destination Module [
n] (Selectable)
Allows a selected module [n] to be configured as a destination module.
Destination Port [
n] (Selectable)
Allows a selected port [n] to be configured as a destination port.
Errors (Toggle)
Allows the user to configure the source modules and ports to either send 
errored frames to selected destination modules and ports ([ON] option), 
or to drop errored frames, and send only valid traffic to the destination 
modules and ports ([OFF] option). The default setting of this field is 
[ON]. 
Status (Toggle)
Allows the user to add or delete the source/destination modules and ports 
selected in the Source/Destination Modules and ports fields.
5.11.1
Displaying the Source and Destination Entries
There can be more than one Port Redirect Function screen depending on 
the number of port redirect entries. Each screen displays up to ten port 
redirect entries. If there is more than one screen of redirect entries, the 
NEXT and/or PREVIOUS command is displayed at the bottom of the 
screen, allowing the user to navigate to the next or previous screen.
To display the next screen, use the arrow keys to highlight NEXT. Press 
ENTER and the next screen of entries is displayed.
To display the previous screen, use the arrow keys to highlight 
PREVIOUS. Press ENTER to view the entries in the previous screen.