Operating Manual for XPR Series Power Supply
Table 3.3 User Diagnostics
Symptom
Check
Further Checks and Corrections
No output and the
display is blank.
display is blank.
Is input voltage within specified
range?
range?
Connect to appropriate voltage source.
See
See
Power switch ON?
Turn on power.
Internal circuit?
See your service technician.
No output but the
display turns on.
display turns on.
OVP LED turned on?
See
Front panel INT LED turned on?
See
OTP LED turned on?
See
Current limit set to zero?
See
Voltage control set to zero?
See
LCL/RMT LED turned on?
If using remote analog control, check
your analog programming source
(
your analog programming source
(
).
Is front panel AC LED turned on?
Connect unit to AC supply in specified
range. See
range. See
Internal circuit.
See your service technician.
Output not adjustable.
Is unit in current limit mode? (CC
LED turned on.)
LED turned on.)
Is unit in remote mode? (RMT LED
turned on.)
turned on.)
If using remote analog control, check
your analog programming source
(
your analog programming source
(
).
Is unit at maximum voltage or current
limit?
limit?
Reduce load for lower voltage or current
requirement.
requirement.
Output voltage
fluctuating or regulation
poor.
fluctuating or regulation
poor.
Is unit at current limit?
Increase current limit setting or reduce
load. See
load. See
.
Is input voltage within specified
range?
range?
Connect to appropriate AC voltage
source.
See
source.
See
Is unit under remote analog control? Ensure program source is stable.
Internal circuit.
Internal circuit.
See your service technician.
Output oscillating.
Internal circuit.
See your service technician.