Operation
User Diagnostics
56 
Operating Manual for XPR Series Power Supply
Table 3.3 User Diagnostics
Symptom
Check
Further Checks and Corrections
No output and the 
display is blank.
Is input voltage within specified 
range?
Connect to appropriate voltage source.
See 
Power switch ON?
Turn on power.
Internal circuit?
See your service technician.
No output but the 
display turns on.
OVP LED turned on?
See 
Front panel INT LED turned on?
See 
OTP LED turned on?
See 
Current limit set to zero?
See 
Voltage control set to zero?
See 
LCL/RMT LED turned on?
If using remote analog control, check 
your analog programming source 
(
). 
Is front panel AC LED turned on?
Connect unit to AC supply in specified 
range. See 
Internal circuit.
See your service technician.
Output not adjustable.
Is unit in current limit mode? (CC 
LED turned on.)
Turn current knob clockwise to increase 
current limit. Reduce load if current is at 
maximum. Se
Is unit in remote mode? (RMT LED 
turned on.)
If using remote analog control, check 
your analog programming source 
(
). 
Is unit at maximum voltage or current 
limit?
Reduce load for lower voltage or current 
requirement.
Output voltage 
fluctuating or regulation 
poor.
Is unit at current limit?
Increase current limit setting or reduce 
load. See 
.
Is input voltage within specified 
range?
Connect to appropriate AC voltage 
source.
See 
Is unit under remote analog control? Ensure program source is stable.
Internal circuit.
See your service technician.
Output oscillating.
Internal circuit.
See your service technician.