Hitachi L100 Manuale Utente

Pagina di 192
L100 Inverter
Getting Star
ted
1–7
L100 Inverter Specifications, continued...       
Item
200V Class Specifications, continued
L100 inverters, 
200V models
CE version
015NFE
022NFE
UL version
015NFU
022NFU
037LFU
055LFU
075LFU
Applicable motor size  *2
kW
1.5
2.2
3.7
5.5
7.5
HP
2
3
5
7.5
10
Rated capacity (240V) kVA *10
2.9
4.1
6.3
9.6
12.7
Rated input voltage
1-phase: 200 to 240V +5%/–10%, 50/60 Hz ±5%,
3-phase: 200 to 240V +5%/–10%, 50/60 Hz ±5%,
 (037LFU, 055LFU & 075LFU 3-phase only)
Rated input 
current (A)
1-phase
16.0
22.5
3-phase
9.3
13.0
20.0
30.0
40.0
Rated output voltage  *3
3-phase: 200 to 240V (corresponding to input voltage)
Rated output current (A)
7.1
10.0
15.9
24
32
Efficiency at 100% rated output (%)
95.3
95.6
95.5
96.1
96.2
Watt loss,
approximate (W)
at 70% output
50
71
118
152
204
at 100% output
70
97
166
216
288
Braking
Dynamic 
braking, approx. 
% torque, (short 
time stop from 
50 / 60 Hz)  *5
100%: 
≤ 50Hz
50%: 
≤ 60Hz
40%: 
≤ 50Hz
20%: 
≤ 60Hz
20%: 
≤ 50Hz
20%: 
≤ 60Hz
Capacitive feedback type, dynamic braking unit and braking 
resistor optional, individually installed
DC braking
Variable operating frequency, time, and braking force
Weight
kg
2.2
2.8
2.8
5.5
5.7
lb
4.85
6.17
6.17
12.13
12.57