Agilent Technologies 6031A Manuale Utente

Pagina di 134
51
Table 3-8.  Secondary Processor Signature Table
DS(0)
P36U
U4-1
U7-15
U9-15
U11-15
DS(1)
2280
U4-2
U7-14
U9-14
U11-14
DS(2)
4277
U4-3
U7-13
U9-13
U11-13
DS(3)
720F
U4-4
U7-12
U9-12
U11-12
DS(4)
6A31
U4-5
U7-11
U9-11
U11-11
DS(5)
662U
U4-6
U7-10
U9-10
U11-10
DS(6)
6020
U4-7
U7-9
U9-9
U11-9
DS(7)
6327
U4-8
U7-8
U9-8
U11-8
DS(8)
1377
U4-39
U7-7
U9-7
U11-7
U2-16
DS(9)
FF99
U4-38
U7-6
U9-6
U11-6
U2-17
DS(10)
236P
U4-37
U7-5
U9-5
U11-5
U2-18
DS(11)
H495
U4-36
U7-4
U9-4
U11-4
U2-19
WR*
9FU7
U4-12
U7-17
WR*
9FF7
U4-13
U9-17
WR*
9FHU
U4-14
U11-17
F817
U4-26
U20-1
36U7
U4-27
U20-16
0562
U4-28
U20-15
ISTX
9F97
U4-11
U2-4, 14
9FH6
U4-17
U2-2
9FH5
U4-16
U2-11
ALE
0000
U4-30
U2-1
AU68
U4-35
+ 5V
9FA8
U4-33,34
Power Section Troubleshooting
Table 3-9 describes the signals at each of the control board test points. The test connector provided in service kit P/N
5060-2865 allows easy connection to each test point. The measurements given here include bias and reference voltages as
well as power supply status signals. It provides conditions for these measurements and gives the components which are the
sources of the signals. Tables 3-10 and 3-11 describe possible symptoms in the power section. Both give lists of circuit
blocks or components which can cause the symptoms shown. The appropriate assembly is also given.
If the supply exhibits a symptom given in Table 3-10 or 3-11, go to the block which pertains to that symptom. If the exact
symptom seen is not in the tables, start with the symptom that seems to be closest to the one observed. The blocks are given
in the Power Section Blocks section starting in Paragraph 3-84. Troubleshooting information for each block will include a
brief description of the circuit. The columns provided are as follows:
NODE:
This column lists the nodes where the measurements should be taken. In some cases this will be
stated as NODE( + ) and NODE(-) where the first is the test node and the second is the reference.
SETUP:
If a certain setup is required for the measurement, it will be given in this column.
MEASUREMENT:
This column indicates what the expected measurement is for the given node.
SOURCE:
If applicable, the components which generate the signal will be provided in this column.