Xerox 100 Manuale Utente

Pagina di 160
Printer requirements and specifications
6-2
 Installation Planning Guide
Outlet configurations
This section discusses specifications for printer outlets and the 
required wall outlet configurations for the USA / Canada and 
internationally. 
NOTE:  All power outlets must be dedicated to this equipment. 
When determining the electrical connections for your printer, 
make sure that:
Each power cord has a separate circuit
The printer power cord configurations match your receptacle
Your electrical outlets are within the required specifications
50 Hz systems: Ensure that power connections are per local 
codes/regulations. 
60 Hz printer outlet voltages
The following table shows the voltages for the outlets on your 
printer. All power outlets must have a dedicated circuit for each 
system equipment piece. Make sure each power cord has a 
separate circuit.
Table 6-2. Printer (60 Hz) voltage requirements at power 
outlet
Service outlet 
configuration
Measurement 
of wiring
Nominal
Range
4 Wire
Line 1 to neutral
120 V RMS
107-127 V RMS
4 Wire
Line 2 to neutral
120 V RMS
107-127 V RMS
4 Wire
Neutral to 
ground
0
0-10  V  RMS
4 Wire
Line 1 to line 2
208 V RMS
182-220 V RMS
4 Wire
Line 1 to line 2
240 V RMS
210-254 V RMS