Casio XJM145 Manuale Utente

Pagina di 63
40
Error Indicators and Warning Messages
Warning messages and indicators let you know what the problem is when a projector error occurs.
When an error occurs, wait until the fan stops before unplugging the AC power cord. If you unplug the 
AC power cord while the fan is still operating, an error may occur when you plug the AC power cord 
back in.
Indicator/Error Message
Description and Required Action
POWER
: Green steady
The projector’s internal temperature is very high. Press the [ESC] key to 
clear the warning message and perform the following steps.
1 Check for any blocking of the projector’s intake vents, exhaust vents 
and airflow vents, and make sure that there is sufficient space around 
the projector. See 
Setup Precautions” in the “Setup Guide”.
2 If there is dust accumulated around the intake vents, exhaust vents 
and/or airflow vents, turn off the projector and remove it. See 
LIGHT
: –
TEMP
: –
Message
: Internal temperature is too 
high. Check projector air 
vents for blockage.
POWER
: Amber flashing J 
Amber steady
Power has turned off automatically due to internal overheating. Perform 
the following steps.
1 Check for any blocking of the projector’s intake vents, exhaust vents 
and airflow vents, and make sure that there is sufficient space around 
the projector. See 
Setup Precautions” in the “Setup Guide”.
2 If there is dust accumulated around the intake vents, exhaust vents 
and/or airflow vents, remove it. See 
If there is no problem with the projector’s vents, confirm that the POWER/
STANDBY indicator is lit amber (without flashing), and then turn power 
back on again. If the error occurs again when you turn power back on, 
contact your retailer or nearest authorized CASIO Service Center.
LIGHT
: –
TEMP
: –
Message
: Internal temperature is too 
high. The projector will 
turn off.
POWER
: Amber flashing J 
Red steady
Power has turned off automatically due to a fan problem. Confirm that the 
POWER/STANDBY indicator is lit red (without flashing) and that the fan 
has stopped. After checking the POWER/STANDBY indicator, disconnect 
the power cord from the projector and wait for all of the projector’s 
indicators to go out. Next, reconnect the power cord and turn projector 
power back on.
If the error occurs again when you turn power back on, contact your 
retailer or nearest authorized CASIO Service Center.
LIGHT
: Red steady
TEMP
: Red steady
Message
: There is a problem with 
the fan. The projector will 
turn off.
POWER
: Amber flashing J 
Red steady
Power has turned off automatically due to a system problem. After 
confirming that the POWER/STANDBY indicator is lit red (without 
flashing), disconnect the power cord from the projector and wait for all of 
the projector’s indicators to go out. Next, reconnect the power cord and 
turn the projector back on.
If the error occurs again when you turn power back on, contact your 
retailer or nearest authorized CASIO Service Center.
LIGHT
: –
TEMP
: Red steady
Message
: A system problem has 
occurred. The projector 
will turn off.