Vicks EDG-4508+ Manuale Utente

Pagina di 112
63
Chapter 7  
1. Select port 1 ~ port 8 if you are using EDG-4508+U. Select port 1 ~ 
port 16 if you are using EDG-4516+U.
2. Key-in the data idle time. The default is 60 seconds. If you want to 
keep connection continually, you can key-in "0". Data idle Time is the 
time period in which the device waits for data. If the EDG-4508+U/
4516+U does not receive data over an established idle time, the 
EDG-4508+U/4516+U will disconnect temporarily. When the data 
comes to the EDG-4508+U/4516+U, it will reconnect automatically. 
Users do not need to reconnect. 
3. Key-in another IP address of networking device which you want to 
connect.
4. Key-in another TCP port of networking device which you want to 
connect. If you want to connect to the port of another EDG-4508+U/
4516+U, you have to note the following information.
TCP port of EDG-4508+U/4516+U: &&&&
TCP port of EDG-4508+U/4516+U's port1: &&&& +1
TCP port of EDG-4508+U4516+U's port2: &&&& +2
For example:
TCP port of EDG-4508+U/4516+U that you want to connect: 5220.
TCP port of Port 1: 5220 +1=5221
TCP port of Port 2: 5220 +2=5222
5. If you want to connect to a PC or any system, you have to key-in the 
TCP port of that PC or system.
How do you restore the firmware to EDG-4508+/4516+?
If you want to restore the firmware to EDG-4508+/4516+, please follow 
below procedure. The EDG-4508+ is taken as an example to explain the 
following procedure.
1. Execute the application "EDG serial download and testing utility". 
Select your model name and IP address, and then press "Download 
FW" button.
2. Click the "Open button" in the Window of "EDG-4508+ Download 
Firmware". Select the right firmware file (*.exf) to download to your 
EDG. (All of the firmware files are located in C:\\Program 
Files\Advantech\EDG COM Port Utility\firmware\ when you install 
the EDG COM port utility.)