ALTINEX MT103-115 Manuale Utente

Pagina di 8
MULTI-TASKER™
400-0182-003
6
INSTALLING YOUR MT103-115
6
Step 1. Turn OFF the power to the Multi-Tasker™ 
enclosure.
Step 2. Slide the MT103-115 into an available slot 
in the Multi-Tasker™. Make sure the card 
fits into place. Secure the card by 
tightening the retainer screws located on 
the top and bottom of the card. 
Step 3. Turn  ON the  power to the Multi-Tasker™ 
enclosure. 
Step 4. The LED on the card panel will turn RED
indicating that the card is in full operation.
Step 5. Connect a VGA cable from the video 
source to the MT103-115 input connector.
Step 6. The power LED will turn GREEN, 
indicating an input signal is present.
Step 7. Connect the MT103-115 output connector 
to the Receiver (MT103-116) thru a 
CAT-5 cable.
OPERATION
7
There is only one adjustment necessary to operate 
the MT103-115. The adjustment is for equalization 
on long cable runs. It is adjustable according to the 
cable length.
The unit will operate successfully as long as cables 
are attached properly and other technical 
specifications are followed.
TROUBLESHOOTING GUIDE
8
We have carefully tested and have found no 
problems in the supplied MT103-115; however, we 
would like to offer suggestions for the following:
7.1 LED IS NOT LIT
Cause 1:
Card cage is not plugged in.
Solution:
Plug  in  the  card cage. If the LED 
turns ON, the problem is solved. If 
not, see Cause 2.
Cause 2:
Card is not plugged in all the way.
Solution:
Push the card in all the way. If the 
LED is still not lit, see Cause 3.
Cause 3:
Card cage slot has a problem.
Solution 1: Test the card in other slots. If other 
slots work, the problem is the card 
cage slot. The card cage may 
require service. Call ALTINEX at 
(714) 990-2300. If the other slots do 
not work, see Solution 2.
Solution 2: Take any other known good card 
with an LED and verify that the slot 
used is good by seeing if the other 
card’s LED lights in that slot. If it 
lights, then the original card may be 
the source of the problem. Call 
ALTINEX at (714) 990-2300.
7.2 NO DISPLAY
Cause 1:
The source has a problem.
Solution:
Check the source and make sure 
that there is a signal present and all 
source connections are correct.  If 
the source is working and there is 
still no display, see Cause 2.
Cause 2:
Cable connections are incorrect.
Solution:
Make sure the cables are connected 
properly. Also, make sure the 
continuity and wiring are good. If 
there is still no display, see Cause 3.
Cause 3:
The display has a problem.
Solution:
Make sure that the display is 
powered. If there is still no display, 
call ALTINEX at (714) 990-2300.