4.5  EEPROM Function Disable 
 
Jumper SEL7 is use to enable or disable EEPROM function. 
 
If this function disable, IR100S-L/LM will use SEL0~SEL4 setting only. 
If this function enable, IR100S-L/LM will use EEPROM setting and jumpers SEL0~SEL4 are ignored. 
 
 
Jumper 
 
Function 
SEL7 
Descriptions 
Disable 
Disable EEPROM function 
Enable 
Enable EEPROM function
 
 
Note:    
1. SEL5 ~ SEL6 are reserved for future use. 
2. Independent of the SEL3 or SEL4, software flow control is automatically used and DTR always active 
during IrLPT connection (this is used for printer host). In this case, if RXD received an X-OFF, TXD 
transmission is blocked. If RXD received an X-ON, TXD transmission may resume. In addition, 
hardware flow control may also be enabled.
 
3. For IrLPT, XON/XOFF flow control is always enabled. This is independent of SEL3 or SEL4. 
4. In IrCOMM 9-wire connection IR100S-L always response DCE line status if line state is changed or 
response Poll for Line Settings via IrLMP control channel. 
Independent of the IR flow control, HOST data flow control and baudrate is not obey IrCOMM control 
parameters.