Wayne-Dalton WDUSB-10 Manuale Utente

Pagina di 42
Updating Secondary Controllers
26
Use the following procedure to update 
secondary controllers in a network 
where ThinkEssentials
®
 is the pri-
mary controller.
It is best practice to update the network 
information in your secondary controllers 
whenever Z-Wave
®
 modules are added 
or deleted from the network by the 
primary controller.  This will improve the 
overall performance of your network and 
the controllers in it.
To update the network and routing 
information in an existing secondary 
controller on your network, follow the 
same procedure as “Adding a controller 
to the network” (see page 23), but put 
the target controller into JoIN NeTWoRk, 
ReCeIVe CoNFIGURATIoN  or 
RePLICATIoN ReCeIVe mode. 
1.  From the Design tab, press the ADD 
DeVICe button.  A message window will 
ask you to press the button on the device 
to add.
2.  Place the secondary controller into 
ReCeIVe RePLICATIoN or CoPY 
FRoM
 mode.  (Please see the User 
Manual or Instruction Manual for the 
specific Z-Wave
®
 controller being 
programmed for detailed programming 
information.)
If the operation is successful, a message 
window will appear stating that the 
device has been successfully added.  
Repeat this procedure if a message 
window states that the module failed 
to be included.  There is No icon for a 
secondary controller.
NoTe:  For your security, the USB 
Z-Wave
®
 Adapter must be within 3 feet 
of the controller to be added. 
NoTe: The process of adding a controller to 
a Z-Wave
®
 network is often referred to as 
SeND CoNFIGURATIoN or RePLICATIoN SeND 
mode.  The overall process is often called 
CoNTRoLLeR RePLICATIoN.
Network Operations
Press ADD DeVICe to add a secondary controller.
oN
oFF
1
2
3
4
5
6
DeLeTe
INCLUDe
example of 
Secondary 
Controller
Device added successfully message window. 
Initiate secondary controller to ReCeIVe RePLICATIoN.