Symbol Technologies 1-PortPower-over-Ethernet Dépliant

Pagina di 2
To t
he Instal
ler
This guide
 is intended f
or th
e tech
nician responsib
le for 
installing the Symbol Po
wer Injector. 
It assumes the technician is
 familiar with basic Eth
ernet LAN-ba
sed 
networking
 and
 de
vice 
installation concepts. This g
uid
e provides 
specifications, 
proce
dures and guidelines to use 
during the inst
allation process. This gu
ide doe
s not provide site-spe
cific
 installation 
procedures. For detaile
d site-specific installa
tion p
rocedures, re
fer to the
 site-specific 
documentatio
n d
erived
 from site 
survey and site network analysis. 
 
Verifying Package Conten
ts
Inspect th
e pa
ckage c
ontents and report any missin
g or
 dama
ged items to your 
sales 
represe
ntativ
e. The packages should c
ontain 
the 
following:
• Po
wer Injector (pt # AP-PSBIAS-1P2-AFR) 
 
•This Power Inje
ctor Installa
tion Guide (72-70762
-01) 
Safety
 Information
Before ope
rating an
y equipmen
t, revie
w this do
cument 
for any haz
ards associate
d with 
installation and use of the device. Also, re
view s
tandard practices 
for 
preve
ntin
g accidents.
•Only trained
 and qu
alified personnel 
shoul
d install and remove the Power In
jector.
•A powe
r cord is not supplied with the de
vice. Use only a correctly rated power cord th
at’ s 
certified, as appropriate
, for the c
ountry 
of 
operation.
• The  
power co
rd must be a
 three-c
onductor 
type (two current carrying 
conductors 
and one 
ground conductor) termina
ted on 
one end by 
an IEC 
60320 applian
ce 
coupler (for 
Power 
Injector con
nection) and on the other
 end
 by a plug
 conta
ining a ground
 (earth) 
contact.
• The po
wer cord 
must be rated 
for a minimu
m of 250V
AC RMS operation, with a 
minimum 
rated curr
ent capcity 
of 5A
 [or a minimu
m wire gauge 
of 18A
WG (0.7
5mm²)].
• The AC wall-socket outlet must
 be near the
 Power
 Inje
ctor 
and 
easily 
accessible.
• The Power Injector Da
ta an
d Da
ta
 & P
owe
r interfaces are qualified as SEL
V (Safety 
Extra-L
ow
 Volt
age) circuits according to 
to IEC 609
50. These
 interfaces can 
only be 
connected 
to SELV 
interfaces on
 other e
quipm
ent. 
Wa
rn
ings
• Rea
d th
e installation instruction
s befo
re con
necting th
e Power Injector 
to a 
powe
r source.
•Follow basic electricity 
safety
 measures wheneve
r conne
cting the Power Inje
cto
r to its 
powe
r source. 
•This product 
relies on o
n th
e building 
installation
 for short-circuit
 (over cu
rrent) 
protection
. Ensure a fuse or circuit brea
ker 
no larger than 120
 VA
C, 3A U.S. (240V
AC, 
1.5A international) 
is used on the phase condu
cto
r.
•A volatg
e mismatch can cause 
equipment dam
age a
nd could 
pose a 
fire haz
ard. If the 
voltage indicat
ed on th
e label is 
different 
from the p
ower o
utle
t voltage, 
do not con
nect 
the Po
wer Injector to
 that pa
rticular outlet.
•The Power Inje
ctor
 Da
ta In
 and Da
ta & Po
wer Ou
po
rts are shielded 
RJ-45 
soc
kets. 
Only RJ-4
5 data con
nectors should
 be conne
cte
d to
 these
 sockets.
Service Inf
ormation
Before using 
the 
unit, 
it must be
 configure
d to
 ope
rate in the facility’ s network and run y
our 
applicatio
ns.  
 If you have a problem 
runnin
g yo
ur 
unit or using
 your equipment, c
ontact 
your 
facility’ s T
echnical 
or Syste
ms Su
pport. If t
here is a problem with 
the equipment, th
ey will 
contact the Symbo
l Su
pport Center:
For the latest
 version of 
this guid
e g
o to
:  htt
p:/
/www.s
ymbol.com/manua
ls/
United St
ates
1-80
0-653-
5350
1-63
1-738-
2400
Canad
a
905-62
9-7226
United Kin
gdom
0800 
328 
2424 
Asia
/Pac
ific
+65-67
96-960
Austr
alia
1-80
0-672-
906 Aus
tria
/Ös
ter
rei
ch
1-505-
5794-
0
Denmar
k/Dan
mark
7020-
1718
Fin
land/Suo
mi
9 54
07 580
Franc
e
01-
40-9
6-52-
21
German
y/Deu
tsc
hlan
d
6074-4
9020
Italy
/It
alia
2-48
4441
Mexic
o/Méx
ico
5-520-
1835
Neth
erlands
/Neder
land
315-
271700
Norw
ay/Nor
ge
+47 2232 437
5
South
 Afri
ca
11-8
095311
Spain
/Es
paña
 91 324
 40 00
 Inside Spain
Sweden
/Sv
erige
844529
00
+34 91 324 40 
00
Outsi
de Spain
Lati
n Ame
ric
a
 Sales
 Support
1-80
0-347-
0178 In
side US
+1-9
54-255
-2610 O
uts
ide US
Europe
/Mid-Ea
st
 Distr
ibu
tor O
perat
ions
Contac
t loc
al d
ist
ribut
or or
 call
+44 11
8 945 73
60
Power Injector
1-Port Power-over
-Ethernet 
 Installation Guide
72-7076
2-01
Revision A  January 
2006
 
(2)
(1)
(3)
(4)
(5)
(6)
Introduction
When users purchase a Symbol WLAN solution, they often need to place access points in 
obscure locations. In the past, a dedicated 24-hour, 90-264 VAC power source was required for 
each access point in addition to the Ethernet infrastructure. This often required an electrical 
contractor to install power drops at each access point location. With the Symbol Power Injector 
solution (pt # AP-PSBIAS-1P2-AFR), centralized power can be provided for devices without a 
local power supply for each.
Product Description
The Symbol Power Injector (pt # AP-PSBIAS-1P2-AFR) is a single-port, 802.3af compliant Power 
over Ethernet hub combining low-voltage DC with Ethernet data in a single cable connecting 
to an AP. The Power Injector’s single DC and Ethernet data cable creates a modified Ethernet 
cabling environment eliminating the need for separate Ethernet and power cables.
The Power Injector is a small lightweight unit with a RJ-45 Ethernet cord input connector from 
the hub on the front right-hand side of the unit and a RJ-45 data and power output connector 
to the AP on the front left-hand side of the unit. On the back of the unit is a 110-220 VAC power 
input.
A separate Power Injector is required for each device comprising the network. 
The Symbol Power Injector supports the following Symbol device product families (all models 
of the those listed):
•AP 100
•AP 200
•AP 300
•AP-5131
Caution - Using the Power Injector with an unsupported Symbol device could 
render the device inoperable and void your warranty.
The Power Injector has the following features:
•Independent power controller (SPEAR™), CPU controller and input (Data) and output 
(Data + Power) shielded RJ-45 connectors
•Supports standard 10/100BaseT Ethernet networks over a standard TIA/EIA-568 
Category 5 (or higher) cabling
•Meets the IEEE 802.3af standard
•Universal AC Input: 110/220 V, 60/50 Hz.
•Minimum port output continuous allowable power of 15.4W at 48V
(minimum 12.95W at the PDTE)
•Underload, overload, short-circuit & under/over voltage port protection.
•Port Status and Main power LED indicators
•Standalone or wall mount installation support
• Interconnection option with other Power Injector units.
Technical Specifications
Physical Specifications
Width
58.5mm
Height
31mm
Depth
145mm 
Weight
450gr
Environmental Specifications
Operating Temperature 
0°C to 40°C (32°F to 104°F)
Storage Temperature 
-20°C to 70°C (-4°F to 158°F) 
Operating Humidity 
10% to 93% Non-condensing 
Storage Humidity 
10% to 93% Non-condensing
Electrical Specifications
Input Voltage 
 90VAC to 264VAC (47Hz - 63Hz) 
Maximum Output Power
.15.4 W
Nominal Output Voltage
 48VDC
Ethernet Interface
Input (Data In)
Ethernet 10/100Base-T 
 
(RJ-45 female socket)
 
Output (Data & Power Out) 
Ethernet 10/100Base-T, plus 48VDC
RJ-45 female socket, with DC voltage
on pairs 7-8 and 4-5
Installation
Preparing for Site Installation
The Power Injector can be installed free standing, on an even horizontal surface or wall 
mounted using the power injector’s wall mounting key holes.
The following guidelines should be adhered to before cabling the Power Injector to the Ethernet 
source and Symbol device:
•Verify the device receiving converged power and Ethernet from the Power Injector is a 
product approved by Symbol (AP100, AP200, AP300 and AP-5131).
•Do not block or cover airflow to the Power Injector.
•Keep the Power Injector away from excessive heat, humidity, vibration and dust.
•The Power Injector is not a repeater, and does not amplify the Ethernet data signal. For 
optimal performance, ensure the Power Injector is placed as close as possible to the 
network data port. Do not configure the cable length between the Ethernet network 
source, the Power Injector and the Symbol AP beyond 100 meters (333ft). 
Cabling the Power Injector
To install the Power Injector to an Ethernet data source and Symbol device:
Caution - Ensure AC power is supplied to the Power Injector using an AC cable 
with an appropriate ground connection approved for the country of operation.
1. Connect the Power Injector to an AC outlet (110VAC to 220VAC).
2. Connect RJ-45 Ethernet cable between the network data supply (host) and the Power 
Injector Data In connector.
3. Connect a RJ-45 Ethernet cable between the Power Injector Data & Power Out connector 
and the Symbol device receiving converged power and Ethernet. 
to AP-5131 LAN 
Port
Data
Power
AP-5131
Power 
Injector
Wireless LAN