DELL 9.7(0.0) Manuale Utente

Pagina di 1039
EXEC Privilege mode
show system brief
3. Start diagnostics on the switch.
diag system unit
When the tests complete, the system displays a syslog message:
00:13:17 : Diagnostic test results are stored on file: flash:/TestReport-
LP-0.txt
00:13:19 : Diagnostic test results are stored on file: flash:/TestReport-
LP-1.txt
00:13:20 : Diagnostic test results are stored on file: flash:/TestReport-
LP-2.txt
00:13:22: %Z9500LC12:0 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on linecard 0
00:13:22 : Recommended to reboot the system after diagnostics!!!
00:13:24: %Z9500LC12:1 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on linecard 1
00:13:25 : Recommended to reboot the system after diagnostics!!!
00:13:25: %Z9500LC12:2 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on linecard 2
00:13:25 : Recommended to reboot the system after diagnostics!!!
00:15:41 : Diagnostic test results are stored on file: flash:/TestReport-CP-
unit.txt
00:15:46: %SYSTEM:LP %DIAGAGT-6-DA_DIAG_DONE: Diags finished on CP unit
00:15:47 : Recommended to reboot the system after diagnostics!!!  
Diagnostic results are printed to a file in the flash using the filename format TestReport-{CP | LP}-
unit-id.txt.
4. View the results of the diagnostic tests.
EXEC Privilege mode
show file flash://TestReport-{LP}-unit-id.txt
Where unit-id specifies the Z9500 CPU:
• Line-card CPU 0 is LP-0.
• Line-card CPU 1 is LP-1.
• Line-card CPU 2 is LP-2.
• The Control Processor is CP.
5. View offline diagnostics.
EXEC Privilege mode
show diag information
Dell#show diag information
Diag information:
Diag software image version:
9.2(1.0B2)
-------------------------------------------------------------------
  Linecard slot  0:     Card diags are done (Card Offline).
  Linecard slot  1:     Card diags are done (Card Offline).
  Linecard slot  2:     Card diags are done (Card Offline).
  Linecard slot  3:     Card diags are done (Card Offline).
-------------------------------------------------------------------  
294