DELL 9.7(0.0) Manuale Utente

Pagina di 1039
• Line-card CPU 2 is LP-2.
• The Control Processor is CP.
Example of a Test Log Report (All Levels) for Control Processor: TestReport-CP.txt
Dell# show file flash://TestReport-CP.txt
         DELL  DIAGNOSTICS-Z9500-CP00  [0]
           PPID                  -- US0WGHX2779513AG00T
           PPID Rev              -- X00
           Service Tag           -- 6NHW6Z1
           Part Number           -- 7520072402
           Part Number Revision  -- H
           SW Version            -- 9.2(1.0B2)
           Available free memory: 2,231,607,296 bytes
                   LEVEL 0 DIAGNOSTIC
eepromTest .................................................. PASS
Starting test: fabricAccessTest ......
+ Access Test for BCM unit 0 : PASSED
+ Access Test for BCM unit 1 : PASSED
+ Access Test for BCM unit 2 : PASSED
+ Access Test for BCM unit 3 : PASSED
+ Access Test for BCM unit 4 : PASSED
+ Access Test for BCM unit 5 : PASSED
fabricAccessTest ............................................ PASS
Starting test: fabricBoardRevisionTest ......
Fabric Board  0 Version = 0x1
Fabric Board  1 Version = 0x1
fabricBoardRevisionTest ..................................... PASS
fabricIdTest ................................................ PASS
fabricPllStatusTest ......................................... PASS
Starting test: fanTest ......
 +Fan tray[0] Sanity test PASS
 +Fan tray[1] Sanity test PASS
 +Fan tray[2] Sanity test PASS
 +Fan tray[3] Sanity test PASS
 +Fan tray[4] Sanity test PASS
fanTest ..................................................... PASS
Starting test: fpgaTest ......
WARNING: FPGA Version must be at least 0x1a to access the status, boot status 
and device id registers
fpgaTest .................................................... PASS
i2cTest ..................................................... PASS
macPhyRegTest ............................................... PASS
Starting test: pcieScanTest ......
 39 PCI devices installed out of 39
pcieScanTest ................................................ PASS
Starting test: psuTest ......
  PSU[0] sensor[0] temperature 37.0 C
  PSU[0] sensor[1] temperature 30.0 C
  PSU[0] sensor[2] temperature 25.0 C
 +PSU[0] test PASS
  PSU[1] sensor[0] temperature 32.0 C
  PSU[1] sensor[1] temperature 29.0 C
  PSU[1] sensor[2] temperature 23.0 C
 +PSU[1] test PASS
  PSU[2] sensor[0] temperature 32.0 C
  PSU[2] sensor[1] temperature 30.0 C
Debugging and Diagnostics
297