Silex Technology 140-00197-100 Manuale Utente

Pagina di 14
 
Installation Silex 
Page 
140-00197-100 Revision 
Chapter 3 
Installation 
Installation Requirements 
The SX-SDCAG must be installed in a device that contains a 9-pin SDIO slot. 
 
The SX-SDCAG has FCC limited single modular approval, which can eliminate the need for you to obtain 
FCC Part 15 Subpart C and E (intentional radiation) approvals for your device. In order to use this FCC/IC 
limited single modular approval for the SX-SDCAG, OEM integrators must: 
 
1.  include “Contains FCC ID: N6C-SXSDCAG, IC: 4908B-SXSDCAG” on the exterior label of your 
device. 
2.  ensure for use in the United States and Canada that the driver for the SX-SDCAG in your product 
disables scanning on channels 12-14, 50-70 and 80-144 by loading a table with disabled 
channels into the SX-SDCAG during initialization. 
3.  ensure the driver does not permit use of channels 12-14, 50-70 and 80-144 in ad-hoc mode in the 
United States and Canada by using the same disabling method. 
4.  use an antenna referred to in appendix A or an equivalent type antenna with equal or lower gain. 
5.  include all required statements in your final product user’s manual (per 15.21, 15.27, 15.105, 
15.407(e), etc) and final product labeling (per 15.19).  Refer to FCC/IC Information in previous 
chapter. 
6.  include following statement “In accordance with 15.407(e), within the 5.15 – 5.25 GHz band, this 
device must be restricted to indoor use to reduce any potential for harmful interference to co-
channel Mobile Satellite Systems.” 
7.  not provide Instructions on how to remove or install the SX-SDCAG to your end users. 
8.  provide regulated +3.3 VDC +/- 5% power to the SX-SDCAG. 
 
If you do not follow the above instructions, then it is your responsibility to obtain the necessary FCC 
approvals. 
 
Installation Procedure 
To install the SX-SDCAG: 
 
1.  Be sure to use the proper antistatic handling techniques.