Modem Configuration and Profile
3-204
G24-L AT Commands Reference Manual
April 15, 2008
The following table shows the S102 parameters.
Example
ATS102? <enter>
030
OK
ATS102=100 <enter>
OK
ATS102? <enter>
100
OK
(This means if there is data for transmission to the terminal, the G24-L drops the Wakeup Out
line, waits 100 ms. and then sends data to the terminal.)
line, waits 100 ms. and then sends data to the terminal.)
S100, Set Minimum Time for Terminal to Fall into Sleep Mode
ATS100 is a terminal minimum time limit for entering sleep mode.
In order to limit the number of interrupts on the DTE side and reduce data sending delay time on
our side, G24-L sends wakeup-out pulse when the interval between one burst of sent/received
data to the other is bigger than specified in ATS100.
our side, G24-L sends wakeup-out pulse when the interval between one burst of sent/received
data to the other is bigger than specified in ATS100.
Command Type
Syntax
Response/Action
Remarks
Set
ATS102 = <value>
OK
The Set command sets the delay before
sending data to the terminal, and
defines a period between sending the
wakeup signal and sending data to the
terminal.
sending data to the terminal, and
defines a period between sending the
wakeup signal and sending data to the
terminal.
Read
ATS102? <value>
OK
The Read command returns the current
value.
value.
Table 3-136: S102 Parameters
<Parameter>
Description
<value>
0 <= value <= 255
The default value is 30 ms.
The default value is 30 ms.
Command Type
Syntax
Response/Action
Remarks
Set
ATS100=<delta>
OK
Or
+CME ERROR: <err>
The set command sets the terminal
minimum time limit for entering sleep
mode.
minimum time limit for entering sleep
mode.
Read
ATS100?
<delta>
OK
The Read command returns the current
ATS100 value.
ATS100 value.