Toshiba Model: GD-1150 Manuale Utente

Pagina di 90
2) Service of Machines
- Basically, be sure to turn the main switch OFF and unplug the power cord during service.
- Be sure not to touch high-temperature sections such as the exposure lamp, the fuser unit, the 
damp heater and their periphery.
- Be sure not to touch high-voltage sections such as the chargers, transfer belt, 2nd transfer roller, 
developer, IH control circuit, high-voltage transformer, exposure lamp control inverter, inverter for 
the LCD backlight and power supply unit. Especially, the board of these components should not 
be touched since the electric charge may remain in the capacitors, etc. on them even after the 
power is turned OFF.
- Be sure not to touch rotating/operating sections such as gears, belts, pulleys, fan, etc.
- Be careful when removing the covers since there might be the parts with very sharp edges 
underneath.
- When servicing the machines with the main switch turned ON, be sure not to touch live sections 
and rotating/operating sections. Avoid exposure to laser radiation.
- Use suitable measuring instruments and tools.
- Avoid exposure to laser radiation during servicing.
Avoid direct exposure to the beam.
Do not insert tools, parts, etc. that are reflective into the path of the laser beam.
Remove all watches, rings, bracelets, etc. that are reflective.
- Unplug the power cable and clean the area around the prongs of the plug once a year or more.
A fire may occur when dust lies on this area.
3) Main Service Parts for Safety
- The breaker, door switch, fuse, thermostat, thermofuse, thermistor, etc. are particularly important 
for safety. Be sure to handle/install them properly. If these parts are shorted circuit and/or made 
their functions out, they may burn down, for instance, and may result in fatal accidents. Do not 
allow a short circuit to occur. Do not use the parts not recommended by Toshiba TEC Corpora-
tion.
4) Cautionary Labels
- During servicing, be sure to check the rating plate and the cautionary labels such as “Unplug the 
power cord during service”, “Hot area”, “Laser warning label” etc. to see if there is any dirt on 
their surface and whether they are properly stuck to the equipment.
5) Disposition of Consumable Parts, Packing Materials, Used Batteries and RAM-ICs
- Regarding the recovery and disposal of the equipment, supplies, consumable parts, packing 
materials, used batteries and RAM-ICs including lithium batteries, follow the relevant local regu-
lations or rules.
6) When parts are disassembled, reassembly is basically the reverse of disassembly unless 
otherwise noted in this manual or other related documents. Be careful not to reassemble 
small parts such as screws, washers, pins, E-rings, star washers in the wrong places.
7) Basically, the machine should not be operated with any parts removed or disassembled.