CHAPTER 2 DEPENDENCE FUNCTIONS
2.3.5
Control by Sequencer
This emulator has a sequencer to control events. By using this sequencer, sampling of
breaks or traces can be controlled while monitoring program flow (sequence). A break
caused by this function is called a sequential break.
breaks or traces can be controlled while monitoring program flow (sequence). A break
caused by this function is called a sequential break.
■
Control by Sequencer
As shown in Table 2.3-4, controls can be made at 3 different levels.
One event can be set for one level.
The sequencer always moves from Level 1 through Level 2 to Level 3. One event can be specified as a
sequencer restart condition.
When the debug function on MB2147-01 is set to Trace Enhancement mode, it is possible to control a trace
by a sequencer.
1. Complete the trace acquisition.
2. Transit to the next block (Only in multi trace mode)
Table 2.3-4 Sequencer Specifications
Function Specifications
Level count
3 levels+ restart condition
Conditions settable for each level
1 event conditions (1 to 16777215 times pass count can be
specified for each condition.)
specified for each condition.)
Restart conditions
1 event conditions (1 to 16777215 times pass count can be
specified.)
specified.)
Operation when conditions established
Branching to another level or terminating sequencer