8–4
Troubleshooting
Fail-Safe Booter
8.4 Fail-Safe Booter
The fail-safe booter provides an emergency recovery mechanism when the primary 
firmware image contained in flash memory has been corrupted. When flash memory 
has been corrupted, and no image can be loaded safely from the flash, you can run 
the fail-safe booter and boot another image from a diskette that is capable of repro-
gramming the flash.
Starting the Fail-Safe Booter
You can start the fail-safe booter in one of two ways:
If the primary firmware image is unavailable when the system is powered on or 
reset, the fail-safe booter runs automatically. When the fail-safe booter runs, the 
system emits a series of beeps through the speaker as beep code 1-2-3; that is, 
one beep and a pause, followed by two beeps and a pause, followed by three 
beeps. After the diskette activity light flashes, insert the AlphaPC 164SX SRM 
Console Firmware
 diskette. The fail-safe booter will load and run the 
AlphaBIOS firmware update utility from this diskette. Proceed to Section 7.4 
and follow the procedure for updating your flash ROM.
You can also start the fail-safe booter manually as follows:
1. Power off your system.
2. Slide switch CF7 to off, as described in Section 3.3.
3. Power on your system.
4. Insert the AlphaPC 164SX SRM Console Firmware diskette into the diskette 
drive.
5. Proceed to Section 7.4 and follow the procedures.
BF
Fail-safe booter is scanning the diskette
1
Fail-safe booter is loading the AlphaBIOS
2
Fail-safe booter is loading the Debug Monitor
3
Fail-safe booter is loading the SRM console 
4
Fail-safe booter is loading the Linux mini-loader
Table 8–2 Post Codes 
(Sheet 3 of 3)
Source
Post Code 
(hex)
Description