Honeywell 08060 / TH106 / TL6061 69-2024 Manuale Utente
08060 / TH106 / TL6061
69-2024 1/11/06 1/3
Programmable Thermostat - Installation and User Guide
This programmable thermostat can be used to control an electric
heating system such as an electric baseboard heater, a radiant ceil-
ing, a radiant floor, a convector, etc.
heating system such as an electric baseboard heater, a radiant ceil-
ing, a radiant floor, a convector, etc.
The thermostat cannot be used under the following conditions:
•
The resistive load is greater than 16.7 A
•
The resistive load is less than 2 A
•
The system is driven by a contactor or relay (inductive load)
•
The system is a central heating system
SUPPLIED PARTS:
•
•
One (1) thermostat
•
Two (2) 6-32 screws
•
Two (2) solderless connectors
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK.
THE INSTALLATION MUST BE PERFORMED BY AN ELECTRI-
CIAN.
POWER PANEL TO AVOID ELECTRICAL SHOCK.
THE INSTALLATION MUST BE PERFORMED BY AN ELECTRI-
CIAN.
All cables and connections must conform to the local electrical
code.
code.
Special CO/ALR solderless connectors must be used when con-
necting with aluminum conductors.
necting with aluminum conductors.
Install the thermostat onto an electrical box.
Install the thermostat about 5 feet high, on an inside wall facing
the heater.
the heater.
Avoid locations where there are air drafts (such as the top of a
staircase or an air outlet), dead air spots (such as behind a
door), or direct sunlight.
staircase or an air outlet), dead air spots (such as behind a
door), or direct sunlight.
Do not install the thermostat on a wall that conceals chimney or
stove pipes.
stove pipes.
The thermostat wires are not polarized; either wire can be con-
nected to the load or to the power supply.
nected to the load or to the power supply.
NOTE:
Always keep the thermostat's vents clean and unobstructed.
n
o
Connect the thermostat wires to the line wires and to the load
wires using solderless connectors for copper wires.
wires using solderless connectors for copper wires.
p
Push any excess wire back into the electrical box.
NOTE:
If necessary, before re-installing the front component, config-
ure the thermostat (see section 3).
q
Return power to heating system.
n
Description
1.
o
Installation
2.
Select the
operating mode
operating mode
Set the time
Time and day
T
emperature
Operating
mode icons
mode icons
Skip a period
Program the
schedule
schedule
Temperature
preset icons
preset icons
Temperature
adjustment
buttons
adjustment
buttons
Temperature
preset buttons
preset buttons
Heating power
indicator
indicator
Periods
Appears when the
setpoint is displayed
setpoint is displayed
Set the day
2-wire installation
4-wire installation
08160
TH106
TL6160
400-106-009-A_69-2024 (Cadet TL6160) ENG.fm Page 1 Wednesday, November 1, 2006 9:54 AM