Hubbell Electric Heater Company CR Manuale Utente

Pagina di 25
 
 
16 
Faulty thermostat. 
Check thermostat adjustment. 
Monitor thermostat as described in 
Section III, Quarterly Inspection. 
Replace if necessary. 
Blown fuse in element fuse 
block, if installed. 
Replace fuse. 
Heating element not working 
on all phases 
Check to see that heating element 
is working on all phases, by 
checking the resistance (ohms) 
value for each element and 
comparing with the chart included 
in Section VI. 
Water temperature below 
settings at all times 
 
Heater improperly sized 
Verify heater is properly sized for 
the flow rate and temperature rise 
of your system. See formulas 
included in Section VI. Replace 
elements with proper size as 
necessary. 
Relief valve discharges 
continuously 
Excessive temperature or 
pressure in tank 
Temperature and pressure relief 
valves are made to operate if the 
water temperature exceeds 210
°F 
or water pressure exceeds the 
pressure rating of the safety relief 
valve. If trouble is excessive 
temperature, then thermostat is not 
shutting off at the right setting and 
thermostat must be replaced.