U32S-5 FPI Direct Vent Gas Insert
COPY OF LIGHTING INSTRUCTION PLATE
OPERATING INSTRUCTIONS
slightly different rates which can cause "ticking" 
and "cracking" sounds. You should also be aware 
that as there are temperature changes within 
the unit these sounds will likely re-occur. Again, 
this is normal for steel fi reboxes.
Blower Thermodisc: 
When this thermally activated switch turns ON 
it will create a small "clicking" sound. This is the 
switch contacts closing and is normal.
Pilot Flame: 
While the pilot fl ame is on it can make a very 
slight "whisper" sound.
Gas Control Valve: 
As the gas control valve turns ON and OFF, a 
dull clicking sound may be audible, this is normal 
operation of a gas regulator or valve.
Unit Body/Firebox: 
Different types and thicknesses of steel will 
expand and contract at different rates resulting 
in some "cracking" and "ticking" sounds will be 
heard throughout the cycling process.
MAINTENANCE  
INSTRUCTIONS
1)  Always turn the gas valve to off before 
cleaning. For relighting, refer to lighting 
instructions. Keep the burner and control 
compartment clean by brushing and 
vacuuming at least once a year. When 
cleaning the logs, use a clean soft paint 
brush as the logs are fragile and easily 
damaged.
2)  Clean (never when unit is hot) appliance, 
door and faceplate with a damp cloth.  Never 
use an abrasive cleaner. The fi nishes on the 
door frame and faceplate may be scratched 
if abrasives are used to clean them.
 
The heater is fi nished in a heat resistant 
paint and should only be refi nished with heat 
resistant paint (not with wall paint). FPI uses 
StoveBrite Paint - Metallic Black #6309.
3)  Make a  periodic check of burner for proper 
position and condition. Visually check the 
fl ame of the burner periodically, making sure 
the fl ames are steady; not lifting or fl oating. 
If there is a problem, call a qualifi ed service 
person. 
4)  The appliance and venting system must be 
inspected before use, and at least annually, 
by a qualifi ed fi eld service person, to ensure 
that the fl ow of combustion and ventilation 
air is not obstructed. 
 
During the annual service call, the burners 
should be removed from the burner tray 
and cleaned. Replace the embers but do 
not block the pilot.
5)  Keep the area near the appliance clear and 
free from combustible materials, gasoline 
and other fl ammable vapours and liquids.
6)  Each time the appliance is lit, it may cause 
condensation and fog the glass.  This 
condensation and fog is normal and will 
disappear in a few minutes as the glass 
heats up.
 
Never operate the appliance without the 
glass properly secured in place or with 
the door open.
7)  Do not use this appliance if any part has been 
under water. Immediately call a qualifi ed 
service technician to inspect the appliance 
and to replace nay part of the control system 
and any gas control which has been under 
water.
8) Periodically check the pilot fl ames. Correct 
fl ame pattern has three strong blue fl ames: 1 
fl owing around the thermopile and 1 around 
the thermocouple, and 1 fl owing across the 
rear of the burner (it does not have to be 
touching the burner).
1) Push in gas control knob slightly and turn to “PILOT” position.
2) Push in control knob all the way and hold in untilthe pilot lights
up. Continue to hold the control knob in for about 20 seconds
after the pilot is lit. Release knob.
3) Push in gas control knob slightly and turn to "ON" position.
4) Turn ON the flame switch.
2) Wait five (5) minutes to clear out any gas. If you then smell gas
STOP! follow “B” in the safety information above on this label. If
you don’t smell gas, go to the next step.
3) Tu rn knob on gas control counterclockwise
to “PILOT”.
4) Pu sh in control knob all the way and hold in. Immediately push
black button on spark igniter until pilot lights. Continue to hold the
control knob in for about 1/2 minute after the pilot is lit. Release
knob and it will pop back up. Pilot should remain lit. If it goes out,
repeat steps 3) and 4).
If knob does not pop up when released, stop and immediately call
your service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas control
knob to “OFF” and call your service technician or gas supplier.
5) Tu rn gas control knob counterclockwise
to “ON”.
6) Us e rocker switch to operate main burner.
DO NOT REMOVE THIS INSTRUCTION PLATE
FOR YOUR SAFETY READ BEFORE LIGHTING
A) This appliance has a pilot which must be lighted by hand, following the instructions below exactly.
B) BE FORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
-
Do not try to light any appliance
-
Do not touch any electric switch, do not use any phone in your building
-
Immediately call your gas supplier from a neighbors phone. Follow the gas supplier’s instructions.
-
If you cannot reach your gas supplier, call the fire department.
C) Us
try to
repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D) Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and
to replace any part of the control system and any gas control which has been under water.
E) This appliance needs fresh air for safe operation and must be installed so there are provisions adequate combustion + ventilation air.
918-474b
OFF
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
or additional information consult a qualified installer, service agency or gas supplier.
LIGHTING INSTRUCTIONS
TO TURN OFF GAS APPLIANCE
THERMOPILE
ELEMENT
THERMO-
ELECTRIQUE
PILOT BURNER
VEILLEUSE
1/
NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: A S5601-2004, New Zealand: NZS 5261)
FOR UNITS NOT EQUIPPED WITH ELECTRIC SPARK:
. Keep burner
appliance.
STOP! Read the safety information above on this label.
FOR ALL PROPANE UNITS AND
UNITS EQUIPPED WITH ELECTRIC SPARK BOXES:
1) Push in gas control knob slightly and turn clockwise
to
“OFF”. Knob cannot be turned from “PILOT” to “OFF” unless
knob is pushed in slightly. Do not force.
1) Turn off the flame switch.
2) Push in the gas control knob slightly and turn clockwise
to “OFF”. Do not force.
3) Turn off all electric power to the appliance if service is to be performed.
You may shut off the pilot during prolonged non use periods to conserve fuel.
l
WARNING:  CHILDREN AND ADULTS 
SHOULD BE ALERTED TO THE 
HAZARDS OF HIGH SURFACE 
TEMPERATURE AND SHOULD STAY 
AWAY TO AVOID BURNS OR CLOTHING 
IGNITION.  YOUNG CHILDREN SHOULD 
BE CAREFULLY SUPERVISED WHEN 
THEY ARE IN THE SAME ROOM AS 
THE APPLIANCE.
CAUTION:  ANY SAFETY SCREEN OR 
GUARD REMOVED FOR SERVICING AN 
APPLIANCE MUST BE REPLACED PRIOR 
TO OPERATING THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE 
MATERIAL SHOULD NOT BE PLACED 
ON OR NEAR THE APPLIANCE.