Chamberlain 3255-2M 1/2 HP Manuale Utente

Pagina di 36
13
LOCK
LIGHT
KG
1
3
9
7
5
KG
1
3
9
7
5
To prevent possible SERIOUS INJURY or DEATH from 
electrocution:
•  Be sure power is NOT connected BEFORE installing door 
control.
•  Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing 
garage door:
•  Install door control within sight of garage door, out of reach 
of children at a minimum height of 5 feet (1.5 m), and away 
from ALL moving parts of door.
•  NEVER permit children to operate or play with door control 
push buttons or remote control transmitters.
•  Activate door ONLY when it can be seen clearly, is properly 
adjusted, and there are no obstructions to door travel.
•  ALWAYS keep garage door in sight until completely closed. 
NEVER permit anyone to cross path of closing garage door.
INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of door at a minimum 
height of 5 feet (1.5 m) where small children cannot reach, 
and away from moving parts of door and door hardware. 
The installation surface must be smooth and flat. If 
installing into drywall (Figure 1), drill 5/32" holes and use 
anchors provided. For pre-wired installations (as in new 
home construction), it may be mounted to a single gang 
box (Figure 2). 
NOTE: After installation, a green or amber 
indicator light behind the cover will indicate proper 
connection. If not lit, the Lock and Light features will not 
function (reverse wires to correct).
1.  Strip 7/16" (11 mm) of insulation from one end of bell 
wire and connect to the two screw terminals on back of 
door control by color: white wire to WHT and white/red 
wire to the RED (Figure 3).
2.  Remove cover by gently prying at slot in the side of the 
cover with a small flat head screwdriver (Figure 4). 
Fasten with 6ABx1-1/4" self-tapping screws (drywall 
installation) or 6-32x1" machine screws (into gang box) 
as follows:
 • 
 
Drill and install bottom screw, allowing 1/8" (3 mm) to 
protrude above wall surface.
 • 
 
Position bottom of door control on screw head and 
slide down to secure. Adjust screw for snug fit.
 • 
 
Install top screw with care to avoid cracking plastic 
housing. 
DO NOT overtighten.
 • 
 
Insert bottom tabs and snap on cover. 
   NOTE: The push bar may stick if the door control is not 
mounted on a smooth surface. If a click is not heard 
when pressing the push bar, loosen the two mounting 
screws or relocate the door control to a smoother 
surface.
3.  
(Standard installation only) Run bell wire up wall and 
across ceiling to motor unit. Use insulated staples to 
secure wire in several places. Do not pierce wire with a 
staple, creating a short or open circuit.
4.  Strip 7/16" (11 mm) of insulation from end of bell wire. 
Connect bell wire to the quick-connect terminals as 
follows: white to white and white/red to red (Figure 5).
   
NOTE: When connecting multiple door controls to the 
opener, twist same color wires together. Insert wires into 
quick-connect holes: white to white and red/white to red.
5.  Use tacks or staples to permanently attach entrapment 
warning label to wall near door control, and manual 
release/safety reverse test label in a prominent location 
on inside of garage door.
NOTE: DO NOT connect power and operate opener at 
this time. The trolley will travel to the full open position but 
will not return to the close position until the sensor beam 
is connected and properly aligned.
To release or insert wire,
push in tab with screwdriver tip
Door Control
Connections
7/16" (11 mm)
Strip wire 7/16" (11 mm)
Red
Grey
White
LOCK
LIGHT
Slot
Drywall Anchors
Insulated Staples 
Screw 6ABx1-1/4"
(standard installation)
Screw 6-32x1"(pre-wired)
HARDWARE SHOWN ACTUAL SIZE
LOCK
LIGHT
Figure 5
Figure 3
Figure 1
Figure 2
Figure 4
MULTI-FUNCTION
DOOR CONTROL (BACK)
REMOVE COVER
PRE-WIRED INSTALLATION
To Replace 
Insert Bottom Tabs First
To Replace 
Insert Bottom Tabs First
24 Volt 
Bell Wire
Top Mounting Hole
Terminal 
Screws
Bell Wire
Bottom Mounting Hole
STANDARD 
INSTALLATION